ML605 Hardware User Guide
www.xilinx.com
21
UG534
(v1.2.1) January 21, 2010
Detailed Description
ML605 Flash Boot Options
The ML605 has two parallel wired flash memory devices as shown in
Figure 1-3
. At ML605
power-up, before FPGA configuration, DIP switch S2 switch 2 selects which flash device,
U4 (BPI) or U27 (Platform Flash), provides the boot bitstream. Typically S2 switch 2 will be
open/OFF to select the U27 Platform Flash. Given that the mode switches (S2 switch
3/M0, switch 4/M1 and switch 5/M2) are set to Slave SelectMAP mode, then U27, driven
at 47 MHz, can load a PCIe core bitstream before a host PC motherboard can scan its PCIe
slots.When S2 switch 2 is closed/ON at power up, the FPGA will be configured from the
BPI flash device U4. Note that U4 address bit A23 is switched by S2 switch 6, which allows
the lower or upper half of U4 to be chosen as a data source.
Table 1-5
shows the connections and pin numbers for the boot flash devices.
Table 1-5:
Platform Flash and BPI Flash Connections
U1 FPGA Pin
Schematic Net Name
U4 BPI Flash
U27 Platform Flash
Pin Number
Pin Name
Pin Number
Pin Name
AL8
FLASH_A0
29
A1
A1 A00
AK8
FLASH_A1
25
A2
B1 A01
AC9
FLASH_A2
24
A3
C1 A02
AD10
FLASH_A3
23
A4
D1 A03
C8
FLASH_A4
22
A5
D2 A04
B8
FLASH_A5
21
A6
A2 A05
E9
FLASH_A6
20
A7
C2 A06
E8
FLASH_A7
19
A8
A3 A07
A8
FLASH_A8
8
A9
B3 A08
A9
FLASH_A9
7
A10
C3 A09
D9
FLASH_A10
6
A11
D3 A10
C9
FLASH_A11
5
A12
C4 A11
D10
FLASH_A12
4
A13
A5 A12
C10
FLASH_A13
3
A14
B5 A13
F10
FLASH_A14
2
A15
C5 A14
F9
FLASH_A15
1
A16
D7 A15
AH8
FLASH_A16
55
A17
D8 A16
AG8
FLASH_A17
18
A18
A7 A17
AP9
FLASH_A18
17
A19
B7 A18
AN9
FLASH_A19
16
A20
C7 A19
AF10
FLASH_A20
11
A21
C8 A20
AF9
FLASH_A21
10
A22
A8 A21
AL9
FLASH_A22
9
A23
G1 A22
AA23
FLASH_A23
26
A24
NC A23