17
Input and output mode
The user can select analogue or digital signal for input and output channels. (I56 and I78 available for
XD8080 revision B model only)
If using AES/EBU, the XD accepts any sample rate on the inputs and will automatically up sample to its
internal clock. The XD has a fixed output sample rate of 96kHz.
Copy channels
Copy channels from the source to the target. When the source and targets are both inputs and outputs, all
audio parameters will be copied. When the Source or the Target is an input while the other is an output, only
the Level, Polarity, Delay, EQ, Crossover, and Channel name are copied.
SOURCE
This is the channel to be copied from.
TARGET
This is the channel to be copied to.
SYSTEM-SETUP
MENU: I/O Mode
I12: A I34: A
I56: A I78:A
O12: A O34: A
O56: A O78:A
SYSTEM-SETUP
MENU: Copy
SOURCE: In1
TARGET: In2
General settings
FREQ MODE
This changes the frequency control mode for EQ and crossover filters. It can be 36 steps/octave or All
frequencies (1Hz resolution).
DELAY UNIT
This sets the time unit for input and output delay to ms, ft, or m.
SYSTEM-SETUP
MENU: General
FREQ MODE: All Freq
DELAY UNIT: ms
XD Series: System menu
Summary of Contents for XD-4080