The NC-SI feature allows a network port to serve as a management port and a
service port. The NC-SI feature is disabled by default and can be enabled
through the iBMC or BIOS.
●
The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault handling.
●
The server chassis panel ensures security of local data.
●
Chassis cover opening detection is supported to enhance security.
●
Intel Execute Disable Bit (EDB) function prevents certain types of malicious
buffer overflow attacks when working with a supported OS.
●
The Intel Converged Boot Guard & Trusted Execution Technology (Intel CBnT)
prevents malicious software attacks based on hardware, prevents the firmware
from being maliciously modified, and prevents the execution of unauthorized
boot blocks. It also allows applications to run in their own independent space
without being affected by other software running in the system, thereby
enhancing security.
●
The secure boot based on the chip RoT implements level-by-level firmware
verification starting from the hardware RoT and builds a complete secure boot
chain.
●
The trusted platform module (TPM) and trusted cryptography module (TCM)
provide advanced encryption functions, such as digital signatures and remote
authentication.
●
The following requirements in NIST SP 800-147B are met:
–
The BIOS firmware digital signature update mechanism is supported. During
the upgrade, the digital signature is verified to prevent unauthorized BIOS
firmware upgrade.
–
The flash security protection mechanism is supported to prevent
unauthorized modification of the flash memory in the OS.
NO TE
The service port with NC-SI enabled supports the following configuration:
● Configuring any network port on the FlexIO card 1, FlexIO card 2, or PCIe NIC (with NC-SI
enabled).
● Enabling, disabling, and setting a virtual local area network (VLAN) ID for this port. The
VLAN ID is
0
and disabled by default.
● Configuring IPv4 addresses (IPv4 address, subnet mask, and gateway) and IPv6
addresses (IPv6 address, prefix length, and gateway) for this port.
Energy Efficiency
●
The server supports 80 Plus Platinum/Titanium PSUs of different energy
efficiency levels. The PSU efficiency reaches 96% at 50% load.
●
Active/standby power supply and HVDC power supply are supported, improving
the efficiency of the power supply system.
●
Efficient voltage regulator-down (VRD) power supplies for boards minimize the
energy loss from DC/DC power conversion.
●
Area-based, Proportional-Integral-Derivative (PID) intelligent fan speed
adjustment and intelligent CPU frequency scaling optimize heat dissipation and
reduce overall system power consumption.
FusionServer 1288H V6 Server
Technical White Paper
2 Features
Issue 10 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
4