![xFusion Digital Technologies FusionServer 1288H V6 Manual Download Page 26](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-1288h-v6/fusionserver-1288h-v6_manual_3317099026.webp)
3
Serial port indicators
NOTE
Reserved and unavailable
currently.
4
PSU indicators
5
UID indicator
-
-
Indicator Description
Table 5-3
Indicators on the rear panel
Silkscreen
Indicator
Description
-
Data transmission
status indicator for
the management
network port
● Off: No data is being transmitted.
● Blinking yellow: Data is being
transmitted.
-
Connection status
indicator for the
management
network port
● Off: The network port is not
connected.
● Steady green: The network port is
connected properly.
-
PSU indicator
● Off: No power is supplied.
● Blinking green at 1 Hz:
– The input is normal, and the
server is standby.
– The input is overvoltage or
undervoltage.
– The PSU is in deep hibernation
mode.
● Blinking green at 4 Hz: The firmware
is being upgraded online.
● Steady green: The power input and
output are normal.
● Steady orange: The input is normal
but there is no output.
NOTE
The possible causes of no power output
are as follows:
● Power supply overtemperature
protection
● Power output overcurrent or short-
circuit
● Output overvoltage
● Short-circuit protection
● Device failure (excluding failure of all
devices)
FusionServer 1288H V6 Server