Service Manual
4.2.2.4
Large jitter
Cause Relevant
Unit
Check Method
Maintenance
Method
Power supply-
main control
board connection
failure
None
Visual check
Connect the
connector.
Power supply fails Power
supply
Tester check
(+24V, GND)
Replace the power
supply.
Motor-main
control PCBA
connection failure
None
Visual check
Connect the
connector.
Motor failure
Motor
Visual check
Replace the
motor.
Table 4.6