Service Manual
4.2.2
Tables
The tables in this section provide detailed troubleshooting information.
4.2.2.1
The Power LED does not go on
Cause
Relevant Unit
Check Method Maintenance
Method
Unplugged from
outlet
None
Visual check
Insert the AC
plug into the
outlet.
AC power
unplugged at
unit
None
Visual check
Insert the AC
cable into unit.
Power switch is
OFF
None
Visual check
Turn the power
switch on.
AC voltage
failure
None
AC outlet voltage
check
None
Power unit AC
input connector
disconnected
None
Visual check
Connect the
connector.
Power switch
connector
disconnected
None
Visual check
Connect the
connector.
Power unit-main
PCBA connection
failure
None
Visual check
Connect the
connector.
Power unit
output voltage
failure
Power unit
Output voltage
(+24V) check
Replace the
power unit
PCBA Failure
Main control
PCBA
Tester check
(+24V, GND)
Remove the
cause or replace
the PCBA.
LED board
LED board-main
PCBA connection
failure
None
Visual check
Connect the
connector
Table 4.3