4.2.2.6
Image unclear
Cause
Relevant Unit
Check Method Maintenance
Method
Remar
k
Lamp too dark
Lamp
Visual check
Replace with a
new lamp.
None
Dirt on calibration
reference plate
Calibration
reference plate
Visual check
Clean the glass
with isopropyl
alcohol.
None
Dirt on calibration
reference plate
Calibration
reference plate
Visual check
Clean the
calibration
reference plate
with isopropyl
alcohol.
None
Dirt on the mirrors
Mirrors
Visual check
Clean the
mirrors with
isopropyl
alcohol.
None
Dirt on the lens
Lens
Visual check
Clean the lens
with isopropyl
alcohol.
None
Table 4.8
4.2.2.7
Frequent paper jam
Cause Relevant
Unit
Check
Method
Maintenance
Method
Remark
Paper setting
failure
Operation
error
Is the paper
correctly set in
the paper
chute?
Educate users
to properly
position the
paper.
None
Paper failure
operation
error
Is the
specified
paper used?
None None
Pad assembly
failure
Pad assembly
Check the pad
assembly for
wear and tear
Replace the
pad assembly/
touch spring
unit.
None
Table 4.9
4-13
Summary of Contents for DocuMate 252
Page 1: ...Sheetfed Scanner Service Manual Version 1 0 ...
Page 13: ...3 2 Main control unit 3 2 1 System diagram Figure 3 2 System block diagram 3 2 ...
Page 40: ...Remove 4 fixing screws Remove the upper housing 5 6 ...
Page 52: ...Service Manual 6 PARTS 6 1 Spare Part Diagram Table 6 1 Spare part diagram 6 1 ...
Page 53: ...6 2 ...
Page 54: ...Service Manual 6 3 ...