4.2.2.5
Reading position deviation
Cause
Relevant Unit
Check Method
Maintenance
Method
Power supply-
main control
board
connection
failure
None
Visual check
Connect the
connector.
Power supply
fails
Power supply
Tester check
(+24V, GND)
Replace the
power supply.
Motor- main
control PCBA
connection
failure
None
Visual check
Connect the
connector.
Motor failure
Motor
Visual check
Replace the
motor
IR sensor
board- main
control PCBA
cable failure
None
Visual check
Connect the
connector
IR sensor
board- main
control PCBA
cable failure
Sensor board-
main control
PCBA cable
Tester or visual
check
Replace the IR
sensor cable
IR sensor
board (SB21)
failure
Sensor board
Tester check
Replace the
PCBA.
Table 4.7