Xenteq ProMax 200 Series User Manual Download Page 1

 

 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 

 

Gebruiksaanwijzing   

NL

  

                       

P ag .   2  

Users manual   

EN

 

                    

P ag e   1 6

  

Gebrauchsanweisung   

DE

 

                                                  S e i t e   3 0      

ProMax 200 

 

                                                          S o f t w a r e   V 1 . 4 . 0

 

 

BATTER

Y

 

CH

A

R

GER

 

Available models: 

 

ProMax 212-25 

ProMax 212-35 

ProMax 212-50 

ProMax 212-70 

ProMax 212-90 

 

ProMax 224-20 

ProMax 224-30 

ProMax 224-50 

ProMax 224-70 

Summary of Contents for ProMax 200 Series

Page 1: ...manual EN Page 16 Gebrauchsanweisung DE Seite 30 ProMax 200 Software V1 4 0 BATTERY CHARGER Available models ProMax 212 25 ProMax 212 35 ProMax 212 50 ProMax 212 70 ProMax 212 90 ProMax 224 20 ProMax...

Page 2: ...Sluit geen verbruikers rechtstreeks aan op de aansluitbouten van de acculader EIGENSCHAPPEN De ProMax 200 heeft een groot aantal eigenschappen en beveiligingen ter bevordering van de gebruiksvriendel...

Page 3: ...arde In de technische specificaties in de bijlage kunt u deze waardes opzoeken Temperatuur De lader is d m v een ventilator tegen een te hoge interne temperatuur beveiligd Mocht de koeling van de vent...

Page 4: ...ke spanningen de accu opgeladen moet worden Aangezien elk merk en type accu eigen laadvoorschriften heeft zijn de vermelde laadprogramma s puur als advies Zo hebben bijvoorbeeld AGM accu s vaak onderl...

Page 5: ...troleer echter altijd of de compensatiefase geschikt is voor de betreffende accu Zo mogen bijvoorbeeld de meeste dichte onderhoudsvrije accu s deze fase niet doorlopen Verder mag deze fase ook niet do...

Page 6: ...eft D m v het herhaaldelijk drukken van de mode knop kunt u kiezen tussen de laadsettingen Laadsetting Suggestie accutype GEL AGM 1 STANDAARD LAADSPANNING fabrieksinstelling OPEN SEMI TRACTIE VOL TRAC...

Page 7: ...r geeft D m v het herhaaldelijk drukken van de mode knop kunt u het laadprogramma ingeven Laadprogramma Suggestie accutype GEL AGM 1 CALCIUM AGM 2 SPIRAAL OPEN SEMI TRACTIE VOL TRACTIE Wacht hierna 10...

Page 8: ...ingen Zorg voor voldoende ruimte rondom de lader en de mogelijkheid van luchtcirculatie Dit is belangrijk voor de koeling van de lader en de afvoer van vrijkomende gassen De Promax 200 is niet geschik...

Page 9: ...angesloten worden De andere verbinding moet gemaakt worden met het chassis Sluit de lader aan op de accu op een afstand van de brandstofinstallatie Controleer of de netspanning van de spanningsbron ov...

Page 10: ...dsproces is afhankelijk van de accukwaliteit accucapaciteit diepte van ontlading de aanwezigheid van gebruikers die nog stroom vragen en van het ingestelde laadprogramma Verder kunnen eventuele foutme...

Page 11: ...der in een wacht stand Als de accuspanning tot 12 65Volt gedaald is schakelt de lader automatisch terug naar de hoofdlading T1 Tijdens deze fase knippert de groene led onder charge process Belangrijk...

Page 12: ...leemoplosser bij het verschijnen van een foutmelding PROBLEEMOPLOSSER Probleem mogelijke oorzaak Handeling E1 Wisselt af met het weergeven van het ingestelde laad programma Aansluitdraden omgepoold Ve...

Page 13: ...bruikers uit of wijzig het laadprogramma Accu cel in sluiting Controleer de accu E4 Lader staat in een thermische stop Het laadproces zal automa tisch weer vervolgt worden als de lader voldoende is af...

Page 14: ...ng van de verbindingen tussen lader en accu Maak de connector schoon of vervang indien nodig Lader levert niet zijn maximale laadstroom Te lage netspanning Controleer de netspanning Onder een spanning...

Page 15: ...orden geleverd met het Smart Value Servicelabel van Xenteq Dit label geeft u extra voordelen en zekerheden op gebied van service Lees meer hierover op onze website Raadplaag altijd eerst de probleemop...

Page 16: ...the connection terminals on the battery charger FEATURES The ProMax 200 contains a wide variety of features and protections to promote the usability and of course also to ensure that the charge proces...

Page 17: ...r users which may be turned on such as lighting for example Because of this the correct charge level can only be indicated 3 min after start up Temperature The Promax 200 is protected against excess t...

Page 18: ...ams listed are purely advice For example AGM batteries often have different charging recommendations We therefore use two recommendations for this battery Always check if the recommended charging prog...

Page 19: ...ot allowed for most sealed maintenance free batteries Furthermore this phase may not be activated when consumers are present during the charging process They can be damaged by the high voltage Therefo...

Page 20: ...By way of repeatedly pressing the mode button it is possible to enter the required charging setting Charge setting Suggested battery type GEL AGM 1 STANDARD CHARGING VOLTAGE factory setting OPEN SEMI...

Page 21: ...ting By way of repeatedly pressing the mode button it is possible to enter the required charge setting Charge setting Suggested battery type GEL AGM 1 CALCIUM AGM 2 SPIRAL OPEN SEMI TRACTION TRACTION...

Page 22: ...explosive gases The charger must be mounted in a dry environment protected from moisture dirt and vibrations Be sure that there is enough space around the charger and provide the possibility of air c...

Page 23: ...rame should be connected firstly The other junction must be made with the frame The connection between the charger and the battery must be made some distance from the fuel installation Check whether t...

Page 24: ...depends on the battery quality battery capacity depth of discharge and the current draw of any present users Furthermore any faults could delay the process A short description of each charging phase...

Page 25: ...battery voltage drops below 12 65 Volt the charger automatically switches back to the boost charge phase T1 During this phase the green LED under charging process blinks Important If you want to remov...

Page 26: ...mp sensor error E6 TROUBLE SHOOTING Problem Possible cause Action E1 alternates with displaying the set charging program Reversed polarization of the cables Remove the connection and attach the cables...

Page 27: ...nd alone Switch off the consumers or change the charging program Short circuit in battery Check the battery E 4 The charger is in a thermical stop The charging process will continue automatically when...

Page 28: ...nation of the connections Clean connections or replace if necessary Charger doesn t deliver its maximum charging current Mains voltage to low Measure the mains voltage Below a voltage of 200VAC 100VA...

Page 29: ...ith the Smart Value service label of Xenteq This service label gives you additional advantages and certainties on service Read more about this on our website Before sending the charger back always adv...

Page 30: ...rs werden die Ladeprogramme ganz einfach eingestellt Es ist kein Problem f r den ProMax wenn mehrere Stromquellen gleichzeitig angeschlossen sind beispielsweise ein Sonnenkollektor oder Dynamo Achtung...

Page 31: ...teht beispielsweise in einem falschen Verh ltnis zur Batteriekapazit t die Batterie nimmt Schaden wenn der Ladevorgang zu lange dauert Sulfatierungs berwachung Das Ladeger t berwacht kontinuierlich de...

Page 32: ...e ausgew hlt werden siehe nachfolgende Erkl rung Im zweiten Schritt wird die Ladespannung bestimmt Im letzten Schritt wird bestimmt ob ein Temperatursensor vorhanden ist Die Kombination aus diesen dre...

Page 33: ...lfat wieder abzubauen ist es f r manche Batterien gut die Kompensationsphase zu durchlaufen In dieser zus tzlichen Ladephase steigt die Ladespannung bei geringem Ladestrom auf ein hohes Niveau n mlich...

Page 34: ...h wiederholtes Dr cken des Modus Knopfes k nnen Sie das dem Akkutyp entsprechende korrekte Ladeprogramm eingeben Ladeprogramm Vorschlag f r Batterietyp GEL AGM 1 NASS werkseitige Einstellung GEOFFNERE...

Page 35: ...n des Modus Knopfes k nnen Sie das dem Akkutyp entsprechende korrekte Ladesetting eingeben Ladeprogramm Vorschlag f r Batterietyp GEL AGM CALCIUM AGM 2 SPIRAL GE FFNETE HALB TRAKTION TRAKTION Warten S...

Page 36: ...Umgebung gesch tzt vor Feuchtigkeit Schmutz und Vibrationen montiert werden Sorgen Sie f r ausreichend Platz um das Ladeger t und die M glichkeit der Luftzirkulation Dies ist wichtig f r die K hlung d...

Page 37: ...erst angeschlossen werden Die andere Verbindung muss zum Chassis hergestellt werden Das Ladeger t an die Batterie anschlie en wobei ein gewisser Abstand von der Treibstoffanlage einzuhalten ist Nachpr...

Page 38: ...t eine Fehler meldung Der Ladevorgang besteht in Abh ngigkeit von den Einstellung aus h chstens f nf Phasen Die Dauer des gesamten Ladevorgangs h ngt von der Batteriequalit t ab der Batteriekapazit t...

Page 39: ...0 schaltet das Ladeger t auf Jogging um Diese Phase verhindert dass ein Akku erm det falls er l ngere Zeit mit einer Erhaltungsladung versorgt wird In dieser Phase wird kein Ladestrom abgegeben Sinkt...

Page 40: ...spannung vorhanden Die Verbindung und die Sicherungen zwischen Akku und Ladeger t kontrollieren Es wurde eine diodentrenn verteiler angeslossen die die Batterie spannung sperrt Verwenden Sie die D ver...

Page 41: ...Verbraucher vorhanden w hrend des Ladevor gangs aber das Ladeger t ist eingestellt fur ein Stand Alone einsetz Schalten Sie die Verbrauchers aus oder ndren das Ladepro gramm Batterie Zelle defekt Kon...

Page 42: ...e wird nicht geladen Das Ladeger t gibt nicht die richtige Spannung und den richtigen Strom ab Das Ladeger t ist im Soft Start 3 Minuten nach Einschaltung des Ladeger ts kann die richtige Ladung abgel...

Page 43: ...Je nach gemessener Temperatur erfolgt eine Kompensation der Endspannung Diese Kompensation muss auf dem Ladeger t dadurch aktiviert werden dass das Ladeprogramm angepasst wird WARTUNG Das ProMax Ladeg...

Page 44: ...llen Im Fall eines Defekts k nnen Sie das Ladeger t Ihrem H ndler zur ckbringen oder direkt an die Adresse auf der R ckseite schicken Das Ladeger t muss frankiert verschickt werden F r die ProMax 200...

Page 45: ...45...

Page 46: ...46...

Page 47: ...47...

Page 48: ...48...

Page 49: ...49...

Page 50: ...50 Xenteq BV Banmolen 14 5768 ET Meijel NL Tel 0031 0 774662067 Fax 0031 0 774662845 www xenteq nl info xenteq nl V1 4 0A...