12 Copyright | C6EU SERIES Installation and Operation Manual, Version 1.6
DC output CHAdeMO (J)
Maximum output power
60 kW
Output voltage range
50 – 500 V
DC
(CHAdeMO)
Maximum output current
125 A
DC
(CHAdeMO)
THD
< 5 % (50 -100% of rated output power)
General
DC connection standard
IEC 61851-1:2011, IEC 61851-23:2014, IEC 61851-24:2014,
IEC 62196-3:2014, ISO 15118, DIN 70121-2014, CHAdeMO 2.0
DC cable length
3.2m; optional 5 / 7 / 10 m (with cable management system)
DC connector type
CCS 2 / CHAdeMO
RFID system
ISO 14443 A&B / ISO 15693 / ISO18092 / ECMA-340
Table 3.2.1 Electrical data of C6EU
3.3
Mechanical data
Mechanical Data
Dimensions (H x W x D)
1750 mm x 615 mm x 740 mm
1981 mm x 764 mm x 872 mm (with cable management
system)
Weight
325 (60 kW) - 395 kg (200 kW)
Volume
0.75m
3
Dimensions including packaging
2100 mm x 850 mm x 900 mm
Weight including packaging
375 (60 kW) - 450 kg (200 kW)
Weight concrete foundation
Min. 450 kg
Mechanical impact protection
IK10
Table 3.3.1 Mechanical data of C6EU