Copyright | C6EU SERIES Installation and Operation Manual, Version 1.6 31
5.4
Indicator lights
On the top of each side of the charger there is a widely visible LED indicator, which
shows different statuses of the charging station.
Lights Pattern
Status
Idle mode
Charging percentage (SOC)
Fully charged (100% SOC)
System preparing
Error
System self-checking
Table 5.4.1 Status of LED indicator
6.
Fault diagnosis
Charging station is equipped with automatic diagnosis function, and the fault will be
directly displayed on the screen and sent to backend.
If the charging station is online, users can call customer service, we will arrange online
engineer for remote repair charging fault.
If the charging station does not connect to network, please call the customer service,
and we will arrange crew to repair and maintenance as soon as possible.
Error Code
Meaning
First-Aid checking
Responsi
bility
0001
Charger communication
failed
Communication between
A8 and DCB failed
Power off the charger and then
check the connection between
DCB and A8 board
EVSE
1005
Power module
communication failed
Check that the DIG switch of the
module is in the correct position,
Check the CAN communication
connection between power
module and DCB module
EVSE
1007
Meter for connector 1
warning
Check the connection and
communication of electricity
EVSE