Installation
3–24
975-0263-01-01
5. Using a jigsaw or other suitable tool, make a hole in the wall or
bulkhead into which to insert the remote panel.
The hole should measure 3 1/4 inches (83 mm) across by 1 1/3 inches
(33 mm) high, with at least 1 1/2 inches (40 mm) of depth to allow space
for the remote panel cord to bend.
6. Plug the male end of the RJ11 extension cord into the XM Series
Inverter.
7. Route the RJ11 extension cord (through the wall or behind the bulkhead,
if necessary) to emerge from the hole you prepared.
8. Plug the jack from the remote panel cord into the female jack on the
extension cord.
9. Secure the remote panel to the wall with the two screws you removed
earlier, or with similarly sized screws appropriate for your mounting
surface.