OPERation Status Register
M370078-01
5-41
5
Shutdown Sub-Register Commands
Query Shutdown Event
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown[:EVENt]?
Query Shutdown Condition
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown:CONDition?
Enable Shutdown Sub-Register
SCPI command:
[:]STATus[<channel>]:OPERation: SHUTdown:ENABle <status-
enable>
Query format:
[:]STATus[<channel>]:OPERation:SHUTdown:ENABle?
Set Shutdown Positive Transition Filter
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown:PTRansition
<status-enable>
Query format:
[:]STATus[<channel>]:OPERation:SHUTdown:PTRansition?
Set Shutdown Negative Transition Filter
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown:NTRansition
<status-enable>
Query format:
[:]STATus[<channel>]:OPERation:SHUTdown:NTRansition?