RC7 & RC7GS Remote Controls
3.0 OPERATION
32
3.
Time Left to Charge
This meter displays the estimated hours required to charge the batteries to
full capacity. The meter is accurate to 1/10 of an hour (6 minutes).
Time Left to Charge:
x.x Hours
Figure 64
Time Left to Charge Display
4.
Set Shore Power
This meter sets the shorepower input (from 5 to 30 amps) so the total
current draw from the charger does not exceed the circuit breaker rating, to
provide the maximum current to the AC loads. Use the Settings push-button
(RIGHT arrow) to change this setting to match the circuit breaker rating of the
AC power source.
NOTE: The maximum current draw from the 3000 kVA unit’s charger is 28 amps.
NOTE: This setting does not prevent the loads from exceeding the shore circuit
breaker rating.
Figure 65
Set Shore Power Display
5.
Generator Start/Stop
The generator can be manually started or stopped from this display by
pressing the On/Off push-button on the RC7GS front panel.
NOTE: Starting the generator from this display overrides all auto-start/stop
function and displays “Man/Stop Only!!” on the User Status menu. Stopping the
generator returns the auto start/stop functions.
Figure 66
Generator Start/Stop Display
Set Shore Power:
5 Amps
Set Shore Power:
30 Amps
822-4A-004
On / Off
Gen Start / Stop:
Press (ON / OFF)