Troubleshooting
975-0125-02-01
4–11
F7
Too many AC loads.
Turn some off, clear
fault, try again.
Escalating
Auto Fault.
Must occur
3 times in
30 seconds
before
becoming
a manual
fault.
AC Overload (PEAK
CURRENT) Shutdown
(AC OUTPUT)
Clear the fault and attempt
restart. Reduce AC loads.
F8
has lost input neutral
connection. See
guide.
Manual
Neutral loss shutdown
Clear the fault and attempt
restart. Check AC input wiring
for presence of a proper neutral
connection and ground
connection. Check the AC
input source to make sure the
neutral is bonded to ground.
F9
Battery voltage is too
high. See guide.
Automatic
DC Over Voltage
Shutdown
Clear the fault and attempt
restart. Ensure battery voltage
is 10–16 VDC at MS2000
terminals. Check all other
charging source outputs,
battery cables.
F10
Battery is too low,
can’t invert.
Recharge battery.
Automatic
DC Under Voltage
Shutdown (Immediate)
occurs if DC voltage is
below 8 volts DC
Clear the fault and attempt
restart. Recharge batteries.
Check battery cable
connections.
F11
Battery is too low,
can’t invert.
Recharge battery.
Automatic
DC Under Voltage
Shutdown occurs if
DC voltage is below
10 volts DC.
Clear the fault and attempt
restart. Recharge batteries.
Check battery cable
connections.
F12
Input AC too high.
Check source, clear
fault, try again.
Automatic
AC Over Voltage
Shutdown (AC Line 1
input)
Clear the fault and attempt
restart. Check AC input
voltage. Check and adjust AC
input high voltage settings.
F13
Input AC too low.
Check source, clear
fault, try again.
Automatic
AC Under Voltage
Shutdown (AC Line 1
input)
Clear the fault and attempt
restart. Check AC input
voltage. Check and adjust AC
input low voltage setting.
F14
Input AC too high.
Check source, clear
fault, try again.
Automatic
AC Over Voltage
Shutdown (AC Line 2
input)
Not applicable for MS2000
Table 4-4
Fault Messages
Fault
Number Message
Fault
Type
Cause
Solution
Summary of Contents for MS2000
Page 1: ...MS2000 Sine Wave Inverter Charger Operation Guide MS2000 ...
Page 2: ......
Page 3: ...MS2000 Sine Wave Inverter Charger Operation Guide ...
Page 8: ...vi ...
Page 18: ...xvi ...
Page 28: ...Introduction 1 10 975 0125 02 01 Figure 1 5 DC Grounding Completed ...
Page 124: ...IX 4 ...
Page 125: ......