Maintenance and Troubleshooting
6–2
975-0466-01-01
Factors Affecting GT Inverter Performance
This section describes several factors that will affect the amount of power that a
properly installed and operating GT Inverter can produce.
PV Array Factors
PV array ratings
PV arrays are rated under standardized conditions, such as specified illumination
(1000 W/m
2
), spectrum of the light (Air Mass 1.5 standard reference spectrum),
and specified temperature (25 °C), that seldom reflect real-world installations.
This is called the STC (Standard Test Condition) rating and is the figure that
appears on the PV module nameplate label.
Expected
performance
A properly designed and installed PV system will produce less than its peak
STC-rated output. Actual production depends on several unavoidable
environmental factors described in this section.
Temperature and
reduced output
PV array temperature affects the output of the entire system. As the temperature
on the array surface heats up, its energy output goes down. Roof-mounted arrays
also collect the heat generated by the roof surface (or trapped under the array) and
will produce less output than pole-mounted arrays, which allow greater air
circulation behind the panels.
Angle of the sun
The angle of the sun in relation to the PV array surface—the array
orientation—can dramatically affect the PV array output. The array energy output
will vary depending on the time of day and time of year as the sun’s angle in
relation to the array changes. Incident sunlight decreases when the sun is near the
horizons due to the greater atmospheric air that it must penetrate. This reduces
both the light intensity that strikes the array’s surface and spectrum of the light. In
general, you can expect only four to six hours of direct sunlight per day.
Partial shade
Shading of only a single module of the array will reduce the output of the entire
system. Such shading can be caused by something as simple as the shadow of a
utility wire or tree branch on part of the array’s surface. This condition, in effect,
acts like a weak battery in a flashlight, reducing the total output, even though the
other batteries are good. However, the output loss is not proportionate to shading.
The GT Inverter is designed to maximize its energy production in all of the above
situations using its MPPT algorithm.
Important:
The GT Inverter will reduce its energy output to protect its electronic
circuits from overheating and possible damage in high heat conditions. For maximum
output in hot climates, mount the GT Inverter in a shaded location with good air flow.
Summary of Contents for GT2.8-AU-QC-230
Page 1: ...Xantrex Grid Tie Solar Inverter Owner s Manual GT2 8 AU QC 230 GT5 0 AU QC 230 ...
Page 2: ......
Page 3: ...Xantrex Grid Tie Solar Inverter Owner s Manual ...
Page 8: ...vi ...
Page 14: ...Contents xii 975 0466 01 01 ...
Page 16: ...xiv ...
Page 18: ...xvi ...
Page 58: ...4 4 ...
Page 70: ...Monitoring the Inverter 5 12 975 0466 01 01 ...
Page 76: ...Maintenance and Troubleshooting 6 6 975 0466 01 01 ...
Page 82: ...A 6 ...
Page 89: ......