975-0767-01-01
3
Introduction
Overload Alarm and Shutdown
During Battery Mode (also
called Inverter Mode), the Freedom X automatically alerts you if the
loads that are connected and drawing power from the unit are close
to approaching the maximum operating limit. If so, the Freedom X
automatically shuts down when the maximum operating limit is
exceeded. See page 56 for precautions.
Over temperature Alarm and Shutdown
During Battery Mode,
the Freedom X automatically alerts you if it is overheating and
approaching the over-temperature shutdown limit. The Freedom X
automatically shuts down when the limit is exceeded. See page 56
for precautions.
Ignition Control
The Freedom X provides two user-selectable
options for ignition control:
•
Ignition Auto-on
: The Freedom X can automatically turn
the inverter on and off in tandem with the vehicle's ignition
circuit or a manually operated remote switch.
•
Ignition Lockout
: The Freedom X features the ability to
inhibit the inverter from operating in the absence of a
voltage signal from a vehicle's ignition circuit. This is
particularly useful if the inverter is required to operate only
when a vehicle's engine is running.
AC Output Frequency
The Freedom X is factory set to 60 Hz
AC output frequency. It can be configured to 50 Hz for use in
regions outside the USA and Canada that operate on 115 VAC/
50 Hz
Freedom X Owners Guide.book Page 3 Wednesday, May 11, 2016 10:32 AM
Summary of Contents for Freedom X 1200 120VAC
Page 2: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Page 12: ...Freedom X Owners Guide book Page x Wednesday May 11 2016 10 32 AM...
Page 14: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Page 77: ...Freedom X Owners Guide book Page i Wednesday May 11 2016 10 32 AM...