![Xantrex Freedom X 1200 120VAC Owner'S Manual Download Page 42](http://html1.mh-extra.com/html/xantrex/freedom-x-1200-120vac/freedom-x-1200-120vac_owners-manual_3226432042.webp)
Figure 5
DC Cable Connections
DC terminal nut
cable lug
DC terminal
DC cable with heat
shrink insulation
covering the lug
stem
DC knockout
hole
enclosure outline (DC compartment side view)
28
Freedom X Owner’s Guide
Basic Installation Procedures
12. Before proceeding, double check that the cable you have just
installed connects the positive DC terminal of the inverter to
the disconnect/battery selector switch, fuse holder, and that the
other end of the fuse holder is connected to the positive
terminal of the battery.
NOTICE
EQUIPMENT DAMAGE
Tighten the nuts on terminals properly. Loose connections cause excessive
voltage drop and may cause overheated wires and melted insulation.
Do not over-tighten the nut on the DC input terminals. Damage to the DC
input terminals may result. The maximum torque setting is
80 in-lbf (9 N-m)
.
Failure to follow these instructions can damage the unit and/or equipment.
NOTICE
REVERSE POLARITY DAMAGE
Check cable polarity at both the battery and the Freedom X before
making the final DC connection. Positive must be connected to positive;
negative must be connected to negative.
Reversing the positive and negative battery cables will blow a fuse in the
Freedom X and void your warranty.
Failure to follow these instructions can damage the unit and/or equipment.
Freedom X Owners Guide.book Page 28 Wednesday, May 11, 2016 10:32 AM
Summary of Contents for Freedom X 1200 120VAC
Page 2: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Page 12: ...Freedom X Owners Guide book Page x Wednesday May 11 2016 10 32 AM...
Page 14: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Page 77: ...Freedom X Owners Guide book Page i Wednesday May 11 2016 10 32 AM...