Freedom X Owner’s Guide
Basic Installation Procedures
Step 5: Connecting AC Output to an Existing AC Circuit
Do not connect the Freedom X to an AC branch circuit that has
high-power consumption loads.
The Freedom X will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than 1200
watts.
A manufacturer-tested and approved GFCI must be connected to the
Freedom X AC output, and GFCI protection must be provided on
every receptacle connected to the AC hard wired installation. Other
types may fail to operate properly when connected to the Freedom
X. See “Ground Fault Circuit Interrupters (GFCIs)” on page 14.
WARNING
FIRE, SHOCK, AND ENERGY HAZARDS
Make sure wiring is disconnected from all electrical sources before
handling. All wiring must be done in accordance with local and national
electrical wiring codes.
Failure to follow these instructions can result in death or serious injury.
NOTICE
EQUIPMENT DAMAGE
Do not connect any AC source (such as a generator or utility power) to
the AC output wiring of the Freedom X.
The Freedom X will not operate if its output is connected to AC voltage
from another source, and potentially hazardous or damaging conditions
may occur. These conditions can occur even if the inverter is off.
Failure to follow these instructions can damage the unit and/or equipment.
Freedom X Owners Guide.book Page 22 Wednesday, May 11, 2016 10:32 AM
Summary of Contents for Freedom X 1200 120VAC
Page 2: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Page 12: ...Freedom X Owners Guide book Page x Wednesday May 11 2016 10 32 AM...
Page 14: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Page 77: ...Freedom X Owners Guide book Page i Wednesday May 11 2016 10 32 AM...