30
Freedom Sequence Intelligent Power Manager Owner’s Guide
Circuit Level Advanced Settings
Load Shed
The
Load Shed
setting here is the same as the setting discussed in “Load
Shed” on page 19. The only difference here is that the change in load shed
setting happens from the circuit-level screen in
Advanced Settings
instead of from the
Config
screen.
Circuit Type
The Freedom Sequence power manager’s circuit relays can control either
AC or DC lines. If the circuit relay controls an AC line, its type is
ACInputOut
. If the circuit relay controls a DC line, its type is
DCInputOut
.
AC relay types cannot be modified to
DCInputOut
. However, a DC relay
type can be modified to
ACInputOut
when that DC relay is used to control
an AC appliance.
AC Line
AC Relays
All AC relays can be associated to either
Line1
or
Line2
.
This is called
Line Association
. You may assign certain AC relays to
Line1
and the remaining AC relays to
Line2
. For example,
Circuit1
,
Circuit3
, and
Circuit5
can be assigned to
Line1
and
Circuit2
,
Circuit4
, and
Circuit6
can be assigned to
Line2
. Default settings are
shown below.
DC Relays
When the type of load circuit is changed from DC to AC, the
line association can either be Line1 or Line2. Default settings are shown
below.
NOTE
: DC relays can be used to control AC loads. For example, a DC relay
can be used to signal an external AC contactor/relay to control an external
AC load circuit.
NOTE
: This setting can only be modified when
Mode
is set to
Standby
.
Model
AC Relays
Types
DC Relays
Types
Four-Circuit
Freedom
Sequence
Circuit1,
Circuit2,
Circuit3,
Circuit4
ACInputOut
(default, cannot
be modified)
Circuit5,
Circuit6,
Circuit7,
Circuit8
DCInputOut
(default)
or
ACInputOut
Six-Circuit
Freedom
Sequence
Circuit1,
Circuit2,
Circuit3,
Circuit4,
Circuit5,
Circuit6
ACInputOut
(default, cannot
be modified)
Circuit7,
Circuit8,
Circuit9,
Circuit10
DCInputOut
(default)
or
ACInputOut
Model
AC Relays
Line Association
[Default]
DC Relays
DC Conn
[Default]
Four-Circuit
Freedom
Sequence
Circuit1,
Circuit2
[Line1]
Circuit5,
Circuit6
[Line1]
a
a.If the
Type
is changed to
ACInputOut
.
Circuit3,
Circuit4
[Line2]
Circuit7,
Circuit8
[Line1]
a
Six-Circuit
Freedom
Sequence
Circuit1,
Circuit2,
Circuit3
[Line1]
Circuit7,
Circuit8
[Line1]
a
Circuit4,
Circuit5,
Circuit6
[Line2]
Circuit9,
Circuit10
[Line1]
a