Model IRS232A 

 

Page 7 

 

© 2002 Xantech Corporation

 

 

 

Figure 4 – IRS232 Options Window 

 

CHANGING THE CODE GROUP MANUALLY WITH AN RC68+ PROGRAMMER (OPTIONAL) 

When multiple IRS232A units will be used together in the same IR Zone, each unit will need to be on a separate 
Code Group to enable each unit to be addressed individually. The code group can either be changed via software 
during a BASE UNIT TRANSFER as mentioned in the previous section or manually. To change manually, 
proceed as follows: 

1.  With an IR sensor connected to IR IN, GND and +12VDC on the IRS232A, as shown in 

Figure 1, 

set the 

Code Group switches on the rear of the RC68+ to “FF”. 

2.  Press the button on the RC68+ of the Code Group to be used for control. (Use the screened characters 

on the buttons for reference. e.g. “10”.) Hold the button for a few seconds and look for confirming talkback 
on IR receiver. 

3.  Change Code Group switch on the rear of the RC68+ to the new code group setting, “10”. 
4.  Create and transfer a project in DRAGON DROP-IR™  for the IRS232A. 
5.  Using the RC68+ test IRS232A for response to the new Code Group. 

 
ASSOCIATING IR TRIGGER COMMANDS WITH ASCII STRINGS 

1.  Select a button in the IRS232 window. It will be highlighted in a blue outline. (Refer to 

Fig. 5

2.  In the RS-232 Command Editor window, place the cursor in the box under the column labeled 01. Type 

the ASCII text command to be sent. If only the HEX code is known, simply place the cursor in the row 
labeled HEX and enter the command. 

NOTE: 

The maximum number of characters in a string is 100. 

3.  Repeat steps 1 and 2 for as many strings as needed up to 36 strings 
4.  It is recommended to test the commands before transferring the project to the unit via BASE UNIT 

TRANSFER. 

 

Summary of Contents for IRS232A

Page 1: ...S232A 6 Changing The Code Group Manually With An RC68 Programmer Optional 7 Associating IR Trigger Commands With ASCII Strings 7 Character Conversion Utility 8 Editing Command Strings 8 Testing Comman...

Page 2: ...Page 2 Model IRS232A 2002 Xantech Corporation Figure 1 Typical System Configuration with Programming Hardware Connections...

Page 3: ...IMUM 486 66 MHz IBM Compatible Computer Pentium versions preferred Windows 95 98 NT 2000 ME XP 5 MB Hard Drive space you will need more as your IR palette libraries expand 16 MB RAM 32 MB preferred Av...

Page 4: ...rom the list and click on the DRAG460 Icon 4 The program loads and opens to the Xantech Dragon Drop IR programming screen SERIAL PORT SELECTION When first launched the Dragon Drop IR software scans th...

Page 5: ...omatically 3 From the Base Unit menu select IRS232 4 A graphic window IRS232 with 36 buttons and an RS 232 Command Editor window appears Figure 2 VERIFYING COM PORT COMMUNICATION WHO AM I FIRMWARE VER...

Page 6: ...allow control of multiple IRS232 units e g having one IRS232 unit set to code group 38 and another set to code group 10 will allow both units to operate independently within the same IR Zone When chan...

Page 7: ...tons for reference e g 10 Hold the button for a few seconds and look for confirming talkback on IR receiver 3 Change Code Group switch on the rear of the RC68 to the new code group setting 10 4 Create...

Page 8: ...nds Any of these methods is adequate for confirming proper operation of the IRS232A Two of these methods can be done before the actual project is transferred to the unit utilizing TEST mode in the Dra...

Page 9: ...ring is being sent by the IRS232A The project created will need to be transferred to the IRS232A Please see Transferring a Project to the IRS232A A PC running a communication program such as Hyper ter...

Page 10: ...68 COMMAND PALETTE a virtual RC68 will appear 4 Select a switch location on the virtual 590 10 It will outline in blue 5 Click the appropriate button on the RC68 The command will appear in the Command...

Page 11: ...MARTPAD AND PALETTE FILES The SmartPad and Palette folders in the DRAG460 directory contain all the files of learned individual IR commands and specific palettes that have created for all projects The...

Page 12: ...proper code group c Verify the proper Code Group Setting in the Dragon Drop IR project d Verify that an actual RS232 command string is programmed in the Dragon Drop IR project under that trigger TABLE...

Reviews: