For safety reasons and to ensure compliance with the warranty conditions, the purchaser is farbidden to 

use the pump should this become faulty or in the event of a sudden variation in the perfarmances of the 

pump itself. 

3. DESCRIPTION OF THE PRODUCT AND USE
3.1 Technical, operational characteristics 

and fields of use 

Submersible electric pumps px and magna series are particularly designed to pump clean and dirty water. 

vort and vorx series are particularly designed to pump clean water, dirty water and sewage.  prnh series, 

with cutter, are suita bi e to cut solids in the liquid to pump, avo id the clogging in small diameter pipes. 

The  free  passage  of  the  impeller,  or  of  the  strainer,  establish  the  maximum  size  of  the  solids  in 

suspension that can be conveyed by the pump. The asynchronous electric motor with squirrel cage rotor 

and class F of insulation (Tmax  155

°

( or 310

°

F),is submersible with protection degree IP68 in compliance 

with  IEC 529 specifìcations.  px  series  is  equipped  with a  permanent  magnet  motor  (12V;  24V  direct 

current DC) 

3.2 

.&. 

Unadvisable uses: ATTENTION

The submersible electric pumps are not suitable far: 
- dry operation;
- operation where air is intaken owing to an excessively low liquid level in relation to the suction parts;
- liquids with a temperature exceeding 40

°

( (104

°

F);

- an immersion depth exceeding 20 m;
- pumped liquids with a pH value of other than 6-1 O (5-8 far series HYDRO);

- pumping infiammable liquids;
- operation in places with a classifìed risk of explosion.

- continuous operation with the electric motor uncovered;
- operati on in a closed piace far longer than 3 minutes sin ce this could cause the electric motor to overheat.

.&, 

Also check that the product confarms to any pertinent locai laws. 

4. STORAGE AND HANDLING

Store the pump in a dry and dust-free piace . 

.&, 

Avoid instability which could be caused by wrongly positioning the product. 

Turn the rotating parts at regular intervals to prevent them from jamming. 
ATTENTION 

For safe storage after a previous installation, the electric pump must be thoroughly 

cleaned (never use hydrocarbon based products far this purpose). 
The electric pump must be handled with care. Use suitable lifting means in compliance 

with the safety provisions in merit, gripping it by the relative lifting points (handles, 

eyebolts). Consult the"Dimensions and weights" chapter in arder to identify the 

weight of the product. 

Never lift the pump by the cable. 

Never subject the cables to sharp bends (the minimum radius of the bend must be 

more than 5 times the dia meter of the cable itself). 

The free ends of the cable must never be immersed or wetted in any way. 

11 

Summary of Contents for PX Series

Page 1: ...ES SUBMESIBLES POUR ASSECHEMENT POUR EAUX USEE N o SERIE SERIES PX MAGNA VORT VORX PRNH Contiene DICHIARAZIONE CE DI CONFORMIT Contains EC DECLARATION OF CONFORMITY EnthaltEG KONFORMITATSERKLARUNG Con...

Page 2: ...Con riserva di modifiche Changes reserved Anderungen vorbehalten Modification reserv es...

Page 3: ...aggio pag 3 5 Installazione pag 4 5 1 Controlli iniziali pag 4 5 2 Caratteristiche dell impianto pag 4 5 3 Collegamenti meccanici serie VORX PRNH pag 4 pag 4 6 5 4 Collegamenti e ragguagli elettrici 7...

Page 4: ......

Page 5: ......

Page 6: ...legamenti elettrici devono essere eseguiti da personale specializzato seguendo tutte le norme e precauzioni vigenti e seguendo le istruzioni riportate nel libretto Tuttiiconduttorigiallo verdidevonoes...

Page 7: ...FT STARTER Durante l avviamento e o l utilizzo la frequenza minima non deve essere inferiore al 70 della nominale Occorre richiedere il motore con avvolgimento elettrico idoneo all utilizzo G d d d V...

Page 8: ...a che le apparecchiature elettriche ed elettroniche AEE giunte a fine vita A devono essere raccolte separatamente seguendo un percorso di smaltimento ecocompatibile e non insieme ai rifiuti urbani mis...

Page 9: ......

Page 10: ......

Page 11: ...g page 11 5 lnstallation page 12 5 1 Preliminary inspections page 12 a 5 2 Plant features page 12 5 3 Mechanical connections series VORX PRNH page 12 5 4 Electrical connections and information page 12...

Page 12: ......

Page 13: ...liquid level in relation to the suction parts liquids with a temperature exceeding 40 104 F an immersion depth exceeding 20 m pumped liquids with a pH value of other than 6 1O 5 8 far series HYDRO pum...

Page 14: ...s and information The electric connection of free conductors must be carried out by qualified personnel who strictly comply with all the current accident prevention provisions in farce the instruction...

Page 15: ......

Page 16: ...EU g This symbol indicates that electrical and electronic equipment EEE that have reached the end A of their Iife must be collected separately following an eco friendly waste disposal route and not wi...

Page 17: ...2 3 Invert two of the three phases direction threephase version 2 4 Compare the setting amperage only value with the one on the 2 4 Wrong overload relay setting pump data plate 2 5 The power supply vo...

Page 18: ......

Page 19: ...ERIE PRNH VORX VORT MAGNA PX SCHALTPLAN EINPHASIGER PUMPEN RERGERG ERG 1O Elektrischer Anschlu plan f r einphasige Elektromotorpumpen 11 Elektrischer Anschlu plan f r Drehstrom Elektromotorpumpen page...

Page 20: ...lass IP68 Q H Hmin Hmax sz tmax Typenbezeichnung Serien Nr Nennspannung V Nennstrom A Frequenz Leistungsaufnahme kW Nennleistung kW Drehzahl lsolationsklasse Motorschutzart Fordermengenbereich 1 s For...

Page 21: ...sser Abwasser und Gulle Die Elektromotor Tauchpumpen der Baureihe prnh mit Schneidwerk eignen sich zum Zerkleinern von schwebenden Feststoffen im gepumpten Wasser um Verstopfungen der Druckleitungen m...

Page 22: ...ellen hindeuten prufen ob das 01 in der richtigen Menge in der Elektromotorpumpe vorhanden ist Falls die Pumpe das erste Mal installiert wird ist auch sicherzustellen dass das 01 keine Verunreinigunge...

Page 23: ...eicht die Stromversorgungsleitung prOfen Drehrichtung nur fiir Drehstrommotoren ACHTUNG Die Drehrichtung der Pumpe mussimmer nach dem Anschluss dem Unterbrechen der Stromversorgungoder Phasenfehlergep...

Page 24: ...tung und die etwaige Reparatur der Elektromotorpumpe durfen nur van quali fiziertem PersonaI vorgenommenwerden dasim BesitzdergeeignetenAusrustungund Ausbildung ist und das den lnhalt dieser Betriebsa...

Page 25: ...en Abfallentsargungsroute und nicht mit unsortiertem Siedlungsabfall HAUSHALTSGERATE Fur die karrekte Sammlung van Abfallen aus Elektra und Elektranikgeraten WEEE wenden Sie sich bitte an die zustandi...

Page 26: ......

Page 27: ......

Page 28: ...MAGNA VORT VORX PRNH PRNH SERIE FONTE PX 11 Raccordement lectrique des pompes monophas es 12 Nombre de conducteurs de c bles par type de pompes page page 34 35 6 3...

Page 29: ...se de rotation Classe d isolation Degr de protection Gamme de d bit 1 s Gamme de hauteur manom trique m Hauteur manom trique minimale ml Hauteur manom trique maximale m Profondeur maximale d immersion...

Page 30: ......

Page 31: ...ts et informations lectriques Les raccordements lectriques doivent tre effectu s par un technicien qualifi en observant scrupuleusement toutes les normes de pr vention des accidents et conform ment au...

Page 32: ......

Page 33: ...par l usure ou la corrosion n est pas couvert par la garantie La non observation de ce qui est indiqu dans la documentation du groupe lectropompe entra1ne l expiration de toute forme de garantie et d...

Page 34: ...nement 2 3 Le moteur tourne dans le sens 2 3 lnverser deux des trois phases contraire uniquement version triphas e 2 4 Calibrage du relais de surcharge 2 4 Comparer l amp rage de erron calibrage avec...

Page 35: ......

Page 36: ...terminal Klemme Betrieb Borne bobinage marche Terminal del devanado de marcha g v giallo verde yellow green gelb gr n vert jaune amarillo verde n nero black schwarz noir negro e marrone brown braun ma...

Page 37: ...Y Connection Y Anschlu GroupementY Conexi nY Colegamento a Connection Anschlu Groupement Conexi n Colegamento a Y Y Connection Y Anschlu GroupementY Conexi n Y Terminali dello statore Stator terminal...

Page 38: ...de siete conductores Elettropompa con cavo a dieci conduttori avviamento diretto 400V 230V Electric pump with 10 lead cable direct start 400V 230V Elektropumpe mit 10 adrigem Kabel direktstart 400V 23...

Page 39: ......

Page 40: ......

Page 41: ......

Page 42: ...60...

Page 43: ...UE 2014 30 UE 2011 65 UE and subsequent changes and additions F r dieses Produkt gibt ELETTROMEK die folgende Erkl rung ab die g ltig ist wenn die im Benutzerhandbuch und der in diesem Handbuch darge...

Page 44: ...XP WATER TECH www pippohydro com...

Reviews: