15.     FAQ’s

a maximum of 1080p, 50Hz. Higher resolutions available 

for graphics-based systems require higher bandwidth that 

may affect transmission of signals as well asincompatibility 

with devices.

IR

1) Check emitters at the IR TX transmitter end 

and receivers at the IR RX receiver end

 – are they 

connected to the correct ports on the matrix and display 

receiver.

2) Is the emitter correctly positioned on the source?

 

Fix the emitter directly over the infrared sensor of the 

source and attach using the adhesive backing.

Note: Locate the infrared source sensor by using a 

flashlight to find small sensor within the facia of the source 

display. If necessary, secure the emitter over the sensor 

with asmall amount of contact adhesive.

3) Is the remote handset powered and sending a 

signal?

Note:

 IR is invisible to the naked eye, so use a digital 

camera/ phone camera to check the remote signal – point 

the camera at the remote control when pressing a button.

The remote transmitter can be seen flashing to indicate a 

signal being sent. Replace batteries if flashing is not seen 

on the digital camera screen.

4)

 IR dropout issues can be due to exterior influences 

emitting infrared radiation that can interrupt IR signals. 

Ensure emitters and receivers are away from the following 

causes of IR interference.

• Direct sunlight, Fluorescent lighting (on cold start up)

• Halogen lighting

• Plasma screens, Candle light

5)

 UTP Termination Issues – ensure cables and RJ45 

terminations are correct and in good condition at both 

transmitter and AMP/receiver ends to see if control is 

established. If so, a possible re-termination of the cable 

could remedy the problem.

6)

 Are WyreStorm emitters and receivers being used? 

The use of third party products/magic eyes may not be 

compatible. Always use WyreStorm components included 

with your purchase or check compatibility of third party 

control systems with your WyreStorm dealer.

7)

 If problems persist, swap out the IR emitters and 

receivers to rule out faults with the units themselves. Use 

emitters you know are fully operational to test working 

condition.

8)

 Reactivate the IR call-back function on your matrix 

and swap IR ports on the matrix to rule out a fault with 

thematrix or connection ports.

9)

 Should IR remain unresponsive, turn off and disconnect 

all cables from the matrix and reconnect zones one at a 

time to assess if one location in particular is the problem. 

If so, run new cables directly to the display – if this fixes 

the problem, it is likely that electromagnetic interference / 

damage to the cable somewhere along the run is causing 

the IR signal to drop out. Investigate and remove EM 

interference from the run or replace damaged UTP cable.

Cat5e or 6?

While our equipment is tested and graded to Cat 5e 

cable standard; tests have shown that better results are 

achieved when using Cat6 cable. The lower American 

Wire Gauge, thicker copper cores ensure better signal 

transfer/Transmission rates. Newly installed cabling should 

always conform to Part P Regulation and BS 7671 (17th 

Edition), and should be terminated to 568B standard.

Can I use a single Cat 5e/Cat 6 cable?

Although conventional transmission is considered to 

be two Cat 5e cables, HDBaseT transmission as used 

only requires a single cable; all of the twin cable features 

are supported with the added benefit of RS232 control 

and Ethernet on 100m/328ft HDBaseT products, with 

70m/230ft HDBaseT products removing Ethernet 

passthrough functionality.

How far can the signal travel?

Under perfect transmission conditions our HDBaseT 

receivers willoperate at 50m, 70m or 100m (@1080p) 

depending on the model used. Perfect conditions means 

no electrical interference, straight cable runs with no 

bends or kinks and no patch panels or wall outlets. If 

some of the above are factors in your installation then 

signal strength and bandwidth can be compromised. If 

a cable run is reaching the upper limit of the receivers’ 

capabilities, then the signal can be boosted by way of 

an Amp set an in-line repeater. 7 times (490m) using 

HDBaseT technology.

What about 3D?

The AMP-001-010, all of our matrix switches and most 

of our extender products will pass-through a 3D Blu-ray 

signal.

Summary of Contents for AMP-001-010

Page 1: ... 0 1793 230 343 1 Instruction Manual Thank you for choosing this WyreStorm product Please read these instructions carefully before installing to avoid complications later WyreStorm HDBaseTTM Class D Digital Audio Amplifier Receiver Repeater Part Number AMP 001 010 ...

Page 2: ...EDID ii Before EDID adjustment iii EDID Pre sets RS232 Application Scenarios i Understanding RS232 Connection Signals ii Zonal IR for Cascading Multiple Independently Controlled AMP units iii Global IR for Cascading Multiple Collectively controlled AMP units iv Hybrid IR for combination of Zonal and Global IR control of multiple AMP units v RS232 Addressing vi Routable RS232 with WyreStorm POH ena...

Page 3: ...g walked on pinched or restricted in any way especially at plug connections 7 Only use attachments accessories specified by the manufacturer 8 Units contain non servicable parts Refer all servicing to qualified service personnel WARNING To reduce the risk of fire electric shock or product damage 4 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 FEATURES AND SAFETY Simp...

Page 4: ...nstallation brackets recommended 1x USB Serial Cable pheonix connector 1 2 3 4 Amplified passive speaker output with spring terminal connections Connecting minimum power handling of 25 Watts RMS per channel accepting 4 6 or 8 Ohm impedance RS232 serial control port for direct and local control of AMP through third party control systems or PC Software provided for connection to a control system see...

Page 5: ...ource LED indication displays currently active audio source L R Line level local audio source input 3 5mm mini jack IR TX control transmitter port For transmitting infrared control signals from central location to control TV function Audio selected 2ch stereo or 2 1ch stereo audio selected 18vDC Power input screw lock connector please use power supply provided Pre out Stereo Audio Output DAC Digit...

Page 6: ...a Cat5e 6 IR Control RS232 IR Control RS232 RS232 IR Receiver IR Receiver IR Receiver AMP 001 010 1 AV Source 2 ARC 3 Local Input HDMI ARC HDMI ARC HDMI ARC AMP 001 010 1 AV Source 2 ARC 3 Local Input 18V 70m Single Cat5e 6 IR Transmitter AMP 001 010 1 AV Source 2 ARC 3 Local Input Multiple HDMI Audio Video Sources Local Audio Source Full 1080p HD Audio Video from centralized source via Cat5e 6 IR...

Page 7: ...nded Multiple Inputs Local Audio Source Local Audio Source Local Audio Source Full 1080p HD Audio Video from centralized source via Cat5e 6 IR Control RS232 IR Control RS232 RS232 IR Receiver IR Receiver IR Receiver AMP 001 010 1 AV Source 2 ARC 3 Local Input HDMI ARC HDMI ARC HDMI ARC AMP 001 010 1 AV Source 2 ARC 3 Local Input 18V 70m Single Cat5e 6 AMP 001 010 1 AV Source 2 ARC 3 Local Input AV...

Page 8: ...entralized source via Cat5e 6 HDMI 18V Speaker Cable to In Ceiling Speakers TX IR 70 RX IR 70 RX IR 70 AMP 001 010 70m Single Cat5e 6 70m Single Cat5e 6 70m Single Cat5e 6 Full 1080p HD Audio Video from centralized source via Cat5e 6 HDMI 18V Speaker Cable to In Ceiling Speakers Speaker Cable to In Ceiling Speakers TX IR 70 RX IR 70 18V AMP 001 010 AMP 001 010 AMP 001 010 In Line and Cascaded with...

Page 9: ...al leg of the distribution a further 70m 230ft or if HDMI output and IR RS232 control only is required As before connect the HDMI sink such as High Definition LED Plasma flat panel display or HD Digital projector to the HDBaseT Output of the HDBaseT Receiver device Repeat process for all AMP 001 010 units installed along your cable run For two way control of connected sources and displays from eit...

Page 10: ...OUT of the AMP 001 010 should be connected to the SUB Input of the AVR and a subwoofer connected to the AVR Likewise speakers should be connected directly to the AVR rather than the spring terminal connectors of the AMP 001 010 Using the Audio Pre Out you can connect the AMP to a multi room audio amplifier system or seperate power amplifier and expand beyond a basic stereo pair The AMP 001 010 can...

Page 11: ...e USB Serial Cable Designate an Address for each Amp that will be connected to the system Choose a number between 0 and 19 to be the address and click Write Addr Click Search Address The Address you typed in should populate under All Addr Click the Right Arrow The Address should show up under selected addr If there is no TV Display connected to the AMP Audio Only needs to be clicked EQ can be set ...

Page 12: ...t via an HDBaseT Transmitter also maintains its own personal audio and ARC Inputs Maintain Central Source Control Central Source Control is achieved with IR Receivers at each display 11i Application Scenarios and Installation Benefits Basic Centralized Source 11ii Extended Centralized Source HDMI HDMI with ARC 18V PSU Cat5e 6 HDBT IN HDBT out TX 7 IR TX hdmi with arc using hdbaset out to cascade c...

Page 13: ...TV news or a Blu Ray movie Same IR receiver function IR receiver eye on displays now handles AMP function matrix switching function central source control As Easy as Single Source Transmission The same principle as a single source with a single transmitter but with the matrix multiplying that process for multiple outputs HDBaseT Output on Each Amp Extend distribution as AMPs also function as a rep...

Page 14: ...as an in line device Simple and cost effective solution for distribution incorporating in wall or in ceiling speakers between an EX 1UTP IR 70 HDBaseT extender set for total distance of 140m 460ft Covers Longer Cable Runs 70m 230ft from Transmitter to AMP then another 70m 230ft from the AMP to the Display Receiver AMP Control Maintained Control of central source and AMP still possible from display...

Page 15: ... a Male Connector while DCE contain a Female Connector although that is not always true a simple way to confirm is to measure Pin 3 and Pin 5 of a DB 9 Connector with a Volt Meter if a voltage of 3V to 15V is achieved the device is DTE If the voltage is on Pin 2 then the device is DCE Note The result for a DB 25 Connector is reversed Please refer to DB 9 to DB 25 conversion table CENTRAL CONFIGURA...

Page 16: ...ge of Logic 1 Mark is between 3VDC to 15VDC while the Logic 0 Space is between 3VDC to 15VDC RS 232 connects the Ground of 2 different devices together which is the so called Unbalanced connection An unbalanced connection is more susceptible to noise and has a distance limitation of 15m 49ft Straight through DB 9 DTE DCE 1 DCD DCD 1 2 RxD TxD 2 3 TxD RxD 3 4 DTR DSR 4 5 GND GND 5 6 DSR DTR 6 7 RTS...

Page 17: ...together from display at the end of the chain global ir all amps controlled together from display at the end of the chain cat5e 6 cat5e 6 18V PS 18V PS 18v psu 18v psu 12ii Zonal IR for Cascading Multiple Independently Controlled AMP units HDBT IN HDMI with ARC U HDBT out ith ARC HDBT out Cat5e 6 cat5e 6 hdbt in hdbt out hdbt out zoned ir each zone with its own ir receiver each amp working indepen...

Page 18: ...dmi with arc hdmi with arc hdbt in hdbt in hdbt out amp set to address 2 amp set to address 1 amp set to address 1 cat5e 6 cat5e 6 18V PSU 18v psu 18v psu 18v psu Final IR Receiver has overall control of all AMPs albeit with variations Each AMP has local IR Control 12iv Hybrid IR for combination of Zonal and Global IR control of multiple AMP units HDBT IN HDMI with ARC U U HDBT out HDMI with ARC H...

Page 19: ... cards each converting to 70m 230ft HDBaseT Outputs More Power As the name suggests the MX PP POH feature Power over HDBaseT outputs enabling power to be passed directly along the Cat5e 6 cable to a PoH enabed receiver so no additional power is required at the display end AMP PoH Passthru The AMP can be used as an PoH passthru device for power from a PoH matrix or transmitter to be carried to the ...

Page 20: ...o be independently controlled which means up to 7 individually addressed AMPs can be connected to each output of the matrix with serial control commands sent centrally through the RS232 port of the matrix to any specific Amp group of Amps within the 8 or 16 separate control zones depending on the matrix model Commands are simply sent to specific AMPs by their address and ignored by others with a d...

Page 21: ...Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 21 RESIDENTIAL RS232 HDBASET ADDRESSING EXAMPLE 12viii Example System Topology showing multiple differently addressed Amps ...

Page 22: ...nt such as the AMP 001 010 perfectly placed to handle this process as communication between display and amplifier is the most important in the system The effective control and management of EDID is essential for the success of any integration with this being achieved in most cases using the default setting on the AMP 001 010 Should device communication or compatibility issues be encountered during...

Page 23: ...by PC Default Factory Setting 1 2 3 4 ON DIP EDID set to copy HDMI OUTPUT EDID 1 2 3 4 ON DIP EDID set to copy HDBaseT OUTPUT EDID 1 2 3 4 ON DIP EDID set to fix 1080p 2ch stereo 3D 1 2 3 4 ON DIP EDID set to fix 1080p 2ch stereo 2D 1 2 3 4 ON DIP Attention Any change to EDID settings will need a power down and power up cycle via the power switch For convenience and ease of installation on the und...

Page 24: ...thin the AMP 001 010 transmitters and receivers allow transmission of 1080p up to 70m 230ft so make sure the cable distance matches the project requirements and is well within the maximum transmission distance of the signal Note If approaching the limits of the transmission capabilities transmission should be extended by using another AMP or receiver to ensure the signal reaches its destination ef...

Page 25: ... such as interference patch panels wall outlets stranded cable use or excessive cable length are likely restricting transmission of a full 1080p signal 15 Blu ray 3D is the equipment used 3D enabled compatible Is a 3D disc being played in a 3D enabled Bluray player or through a compatible amplifier 16 Colour distortion a pink or green screen indicates an incompatibility between colour spacing form...

Page 26: ... IR emitters and receivers to rule out faults with the units themselves Use emitters you know are fully operational to test working condition 8 Reactivate the IR call back function on your matrix and swap IR ports on the matrix to rule out a fault with thematrix or connection ports 9 Should IR remain unresponsive turn off and disconnect all cables from the matrix and reconnect zones one at a time ...

Page 27: ...20p 1080i signal These HDMI cables are NOT recommended All WyreStorm equipment support HIGH SPEED or category 2 HDMI cables that have been tested to perform at speeds of 340Mhz or up to 10 2Gbps which is the highest bandwidth currently utilised over an HDMI cable and can successfully handle 1080p signals including those at increased colour depths and or increased refresh rates from the Source High...

Page 28: ...cated below starting from the original date of purchase either a Repair the product with new or refurbished parts or b Replace it with a new or refurbished product Limited warranty period All WyreStorm products are covered by a 2 year PARTS and LABOUR warranty During this period there will be no charge for unit repair replacement of unit components or replacement of product if necessary The decisi...

Page 29: ...isted here are not exclusive but are for illustration only Parts and service not covered by this limited warranty are not the responsibility of the warrantor and should be considered the responsibility of the individual Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 29 ...

Page 30: ...Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 30 INSTALLATION NOTES ...

Page 31: ...Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 31 INSTALLATION NOTES ...

Page 32: ...N 38133 Tel 901 384 3575 Fax 901 384 3574 Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 Fax 44 0 1793 230 583 WyreStorm Technical Support US 86 6677 0053 UK 44 0 1793 238 338 Email support wyrestorm com We reserve the right to change specification or product dimensions at any time www wyrestorm com WyreStorm Offices US Office 6991 Appling Farms Parkway Suite 104 Mem...