FKE003

 

 
 

Product information 

 

Page 2 of 8 

Subject to technical changes 

FKE003_V2.2_PI_2018-01_EN 

Writing conventions 

Symbol Meaning 

 CAUTION! 

Avoid the described hazard: Otherwise 

minor

 or 

medium

 bodily injury or 

property damage will result. 

 WARNING! 

Avoid the described hazard: Otherwise there is danger from 

electric voltage

 that 

can lead to death or 

serious

 bodily injury. 

For your safety 

For safe operation and to avoid personal injury and equipment damage through operating error, 
always read these instructions, become familiar with the device, and follow all safety instructions on 
the product and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG 
Elektronische Systeme. Keep these instructions ready to hand for quick reference and pass them on 
with the device if the product is sold. 

Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in case of improper use or use for 
other than the intended purpose. 

Target group 

These instructions are intended for service technicians. 

Intended use 

The FKE003, which is installed in refrigerators, is a field module for cold 
locations. 

 

 

WARNING! 
Danger to life from electric shock and/or fire! 

 

Switch off the power to the entire plant when installing, wiring or removing! Otherwise a 
mains voltage and/or external voltage may still be present even if the control voltage is 
switched off! 

 

The wiring of the device should be carried out only by a qualified electrician! 

 

Use only the correct tools for all work! 

 

Check all wiring after connection! 

 

Take note of the maximum loads on all connections! 

 

Never expose the device to moisture, for example due to condensation or cleaning 
agents! 

 

Take the device out of operation if it is faulty or damaged and is therefore compromising 
safe operation! 

 

Do not open the device! 

 

Do not repair the device yourself! If required, send it in for repair with an exact 
description of the fault! 

 

 

CAUTION! 
Electromagnetic interference can cause faults! 

 

Use only shielded data lines and place them far away from power lines! 

 

 
 
 
 
 
 

 

Software revision and validity of documentation 

Software version 

 

V2.2 2018-01 

Documentation 

status

 

Any software versions not listed are special solutions for individual projects and are not described in detail in this document. 
This document automatically ceases to be valid if a new technical description is issued. 

Manufacturer:

 Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid 

For further information, see our website at 

www.wurm.de

 

Summary of Contents for FKE003

Page 1: ...ctronic relay valve controller 230V or ATV230 valve actuation 230V Control of one evaporator per module Integrated temperature display Tool free front installation Fixed input output allocation for se...

Page 2: ...ric shock and or fire Switch off the power to the entire plant when installing wiring or removing Otherwise a mains voltage and or external voltage may still be present even if the control voltage is...

Page 3: ...rol elements 5 4 Device operation 5 4 1 Activating the advanced level 5 4 2 Selecting parameters 5 4 3 Set parameter 6 4 4 Set module number 6 4 5 Block keys against unauthorised operation 6 5 Paramet...

Page 4: ...for the FKE003 Cables Application ZCB C TR 0 6 Controller transformer 0 6m ZCB C TR 2 0 Controller transformer 2 0m ZCB C REL2M 5P Controller load 5 pin ZCB C DI 2 0 Controller digital inputs 2 0m ZC...

Page 5: ...Advanced level will flash for as long as the level is released P P 5s 2 To return to the advanced level press the P key again for 5 seconds If no key is pressed within 2 minutes the display automatic...

Page 6: ...ed within 2 minutes the display automatically returns to the standard level and parameter change is disabled The jump back is always made to the temperature display 4 4 Set module number For easier se...

Page 7: ...ure of suction gas sensor S4 P05 Actual value 4 20mA 0 25 5 Current on 4 20mA input resolution 0 25 5mA P06 Actual value 0 10V output 0 100 Triggering of the 0 10V output resolution 0 100 P07 Sensor t...

Page 8: ...d connection supply air return air defrost limit 1 x TRK EEV 7ST suction gas Analogue input 4 20mA output voltage 18V max 22mA Digital inputs 3 x potential free contact 1 x cold location off 1 x 2nd s...

Reviews: