1

 

Circuit diagram ......................................................................................................................... 3

 

2

 

Installation / connections ........................................................................................................ 3

 

3

 

Display and control elements .................................................................................................. 5

 

4

 

Device operation ....................................................................................................................... 5

 

4.1

 

Activating the advanced level ........................................................................................ 5

 

4.2

 

Selecting parameters .....................................................................................................  5

 

4.3

 

Set parameter ................................................................................................................ 6

 

4.4

 

Set module number ....................................................................................................... 6

 

4.5

 

Block keys against unauthorised operation ................................................................... 6

 

5

 

Parameter .................................................................................................................................. 7

 

6

 

Fault messages and emergency programs ........................................................................... 8

 

7

 

Technical data ........................................................................................................................... 8

 

 

1 Circuit 

diagram 

 

Installation / connections 

28

150 x 32

0,

6

 ... 3

,5 

61

72

120

158

120

 

Installation section 

Summary of Contents for FKE003

Page 1: ...ctronic relay valve controller 230V or ATV230 valve actuation 230V Control of one evaporator per module Integrated temperature display Tool free front installation Fixed input output allocation for se...

Page 2: ...ric shock and or fire Switch off the power to the entire plant when installing wiring or removing Otherwise a mains voltage and or external voltage may still be present even if the control voltage is...

Page 3: ...rol elements 5 4 Device operation 5 4 1 Activating the advanced level 5 4 2 Selecting parameters 5 4 3 Set parameter 6 4 4 Set module number 6 4 5 Block keys against unauthorised operation 6 5 Paramet...

Page 4: ...for the FKE003 Cables Application ZCB C TR 0 6 Controller transformer 0 6m ZCB C TR 2 0 Controller transformer 2 0m ZCB C REL2M 5P Controller load 5 pin ZCB C DI 2 0 Controller digital inputs 2 0m ZC...

Page 5: ...Advanced level will flash for as long as the level is released P P 5s 2 To return to the advanced level press the P key again for 5 seconds If no key is pressed within 2 minutes the display automatic...

Page 6: ...ed within 2 minutes the display automatically returns to the standard level and parameter change is disabled The jump back is always made to the temperature display 4 4 Set module number For easier se...

Page 7: ...ure of suction gas sensor S4 P05 Actual value 4 20mA 0 25 5 Current on 4 20mA input resolution 0 25 5mA P06 Actual value 0 10V output 0 100 Triggering of the 0 10V output resolution 0 100 P07 Sensor t...

Page 8: ...d connection supply air return air defrost limit 1 x TRK EEV 7ST suction gas Analogue input 4 20mA output voltage 18V max 22mA Digital inputs 3 x potential free contact 1 x cold location off 1 x 2nd s...