4-1
4 MACHINE OVERVIEW
Specifications
Engine
•
See your engine owner’s manual
•
Full speed 3600 +/- 50 RPM
•
No load/Idle: 1550 RPM
Electrical System
•
Charging System: Internal stator coil
•
Battery Type: Maintenance free
•
Battery Voltage: 12 Volts
•
Fuses: Two, 20 amp blade type
Drive System
•
Hydro Gear 12cc variable displacement piston
pumps
•
Hydro Gear 15 cu. in. wheel motors
Hydro Oil System
•
Hydro Oil: full SYNTHETIC l:Mobil-1 15W-50
•
Hydro Filter: Spin-on, 25 micron, no bypass
•
Tank Fill Level: Until fluid is visible in the sight
glass
Fuel System
•
Capacity: 8 Gal. (30.2 L).
•
Type of Fuel: Unleaded regular gasoline,
minimum 85 octane. Do not use gasoline
containing more than 10% ethanol. Do not mix
oil with gasoline.
•
Fuel Filter: In line.
•
Fuel shut off: On, Off located on fuel tank.
Speeds
•
Forward 9.5 mph (15.3 km h).
•
Reverse 5.5 mph (8.9 km h).
General Dimensions
48” Deck 52” Deck 61” Deck
Width, Chute down
74.5”
77.5”
86.5”
Width, Chute up
62”
65”
74”
Length
65”
66”
67”
Weight
900 lbs
920 lbs
980 lbs
Torque Specifications
Critical Application
Thread Locker Torque (ft-lbs)
Wheel motor bolts
Loctite 2760
40-50
Clutch to engine
shaft
Loctite 2760
50-55
Wheel hub to wheel
motor
N/A
138-158
Wheel lug nuts
N/A
80-90
Split Hub (Spindle &
Drive)
N/A
13-17
Blade Bolts
N/A
70-80
Engine Mounting
Bolts
Greased
35
Caster Wheel Bolt
N/A
38
Caster Yoke Pivot
N/A
38
Pump Pulley
N/A
14
Pump Bypass Valve N/A
42 in.-lbs.
Safety Interlock System
The machine is equipped with a start interlock system. The PTO must be disengaged; brake applied and
control levers in the neutral position in order to start the machine. With the brake applied, the controls are
locked in the neutral position.
If the safety-interlock switches are disconnected or damaged, the machine could operate
unexpectedly, causing personal injury. Do not tamper with the interlock switches. Check the
operation of the interlock switches daily and replace any damaged switches before operating the
machine.
Digital Hour Meter
Hour meter counts the time that the ignition switch is on AND the platform is occupied. Operating/reset
instructions:
•
Default display: Hours
•
Press once (TMR1): Timer 1, press for 3 sec to reset
•
Press twice (TMR2): Timer 2, press for 3 sec to reset
•
Press three times (svc ENG): Will display time remaining until next service point, hold down to reset. The
first interval is 8hr, thereafter 100hr. Beginning 5hr before service point the meter will flash “svc ENG, in
[remaining hours]” every 5 seconds.
•
Shut off engine: Will display how many times the engine has started.