PH: 866.476.9217
13
Figure 5: Venturi Section of Lubricator
TO ADJUST OIL FEEDER WITH ASSEMBLY (A-C-E)
1.
Depressurize Service Unit, then loosen Lubricator's Bowl Ring Nut by hand.
Remove Bowl using Ring Nut. Loosen Locknut (B);
2.
Increase oil mist delivery by turning Adjusting Nut (C) up to raise Feeder Wick
with (A) into venturi, or turn Adjusting Nut (C) down to decrease oil mist
delivery;
3.
Tighten Locknut (B). The height of the Feeder Wick (A) in the venturi is visually
indicated by the relative position of the Marking Notch (D) on Adjusting Nut (C)
to the bottom of Locknut (B);
4.
Reattach Bowl using Ring Nut, be sure O-ring Seal is correctly set in Lubricator
headgroove. Tighten Bowl Ring Nut by hand. (Reassemble carefully to avoid
stripping and cross threading.)
IMPORTANT
For Food Service applications you must use a
high-quality Food Grade Air Tool Oil. Contact
your WORKMASTER Distributor for product
recommendation.