![Workhorse Powerhouse Quartz 2608 Owner'S Manual Download Page 19](http://html1.mh-extra.com/html/workhorse/powerhouse-quartz-2608/powerhouse-quartz-2608_owners-manual_997067019.webp)
Recirculation System
3730 E. Southern Avenue, Phoenix, AZ 85040 USA
800-778-8779
Workhorseproducts.com
19
All Powerhouse Quartz Dryers are equipped with an air recirculation system to convert radiant heat to con-
vection heat. Convection heat is ideal for garment curing as it completely envelopes the garment and cures
the ink more evenly.
The diagram above shows the path of the circulating air. Drawn thru a center mounted blower motor the air
is pushed through internal air chambers and down through the quartz element banks. The radiant heat from
the elements is now transferred into the air converting it into convection heat.
General use of the dryer will cause lint and
debris from garments and the surrounding
atmosphere to collect inside the internal air
chambers. Locate the blower motor mount-
ed externally on the bottom of the heat
chamber. Remove the two screws securing
the motor mount. The motor assembly will
swing out of the way allowing the removal
of any lint or debris from the blower wheel
and internal air chambers.
Workhorse Products recommends performing this routine maintenance every three to six
months to maintain optimum performance of your dryer.