Before turning the dryer on make sure that the belt is empty and all of the switches on the front panel are
in the off position.
1. Heaters: Turns on/off the quartz elements that are located inside of the dryer.
2. Flash: Turns on 2 to 4 (depending on the dryer model) elements for a quick burst of heat as the garments enter the
dryer.
3. FWD/REV: Controls the direction of the belt. This may affect the belt tracking and additional adjustments may be
needed to maintain proper belt tracking when changing the direction of belt travel.
4. Conveyor Speed: Controls the speed of the belt based on a percentage scale. For example, setting the knob at 40
means the belt is running at 40% of the maximum output voltage of 90 VDC. This is the factory recommended ini-
tial speed setting.
5. Temperature Control: The digital temperature control regulates the oven chamber temperature. The duel display
shows both the current (red) and set temperature (green). When the dryer is coming up to temperature a small
green indicator light labeled “OUT” will be illuminated. The factory recommended initial temperature setting is 310
degrees Fahrenheit. See page 28-29 for detailed functions.
6. Main Disconnect: Controls the main input power to the dryer. When the main disconnect for the dryer is turned
on (red handle up) the belt, recirculation motor, cooling motor and temperature control may be operator.
When turning off the dryer, turn the “HEATERS” switch off first. Allowing the belt to run for 10 to 15 minutes with
the elements off will allow the oven chamber to gradually cool down. Failure to follow this procedure may result in
damage to the dryer and may pose a fire hazard.
Always check garment and ink manufacturers guidelines for proper garment curing and temperatures.
Please note that the actual temperature displayed by the controller is not the temperature of the garments in the oven
chamber. The surface temperature of the garments may be significantly higher than the actual oven chamber tempera-
ture. Workhorse Products carries a non contact infrared digital thermometer to accurately measure the surface tem-
perature of your garments. Please call customer service today for price and availability!