6 720 610 597 GB (03.02)
Appendix
49
10.3 Heating/hot water output settings
ZWBR 7-30 N.G.
10.4 Heating/hot water output settings
ZWBR 11-30 L.P.G
10.5 Heating/hot water output settings
ZWBR 11-35 N.G.
10.6 Heating/hot water output settings
ZWBR 14-35 L.P.G
Natural gas G20
Display
code
Heat output,
kW
Heat input,
kW
Gas vol. flow
rate (l/min at
t
V
/t
R
= 80/60˚C)
30
8.8
8.9
15.5
40
11.7
11.8
20.7
50
14.6
14.8
25.8
60
17.5
17.7
31.0
70
20.4
20.7
36.1
80
23.4
23.6
41.3
90
26.3
26.6
46.5
100
29.2
29.5
51.6
Table 20
Propane
Display
code
Heat output,
kW
Heat input,
kW
40
11.7
11.8
50
14.6
14.8
60
17.5
17.7
70
20.4
20.7
80
23.4
23.6
90
26.3
26.6
100
29.2
29.5
Table 21
Natural gas G20
Display
code
Heat output,
kW
Heat input,
kW
Gas vol. flow
rate (l/min at
t
V
/t
R
= 80/60˚C)
30
10.5
10.7
18.6
40
14.1
14.2
24.9
50
17.6
17.8
31.1
60
21.1
21.3
37.3
70
24.6
24.9
43.5
80
28.1
28.4
49.7
90
31.6
32.0
55.9
100
35.1
35.5
62.1
Table 22
Propane
Display
code
Heat output,
kW
Heat input,
kW
40
14.1
14.2
50
17.6
17.8
60
21.1
21.3
70
24.6
24.9
80
28.1
28.4
90
31.6
32.0
100
35.1
35.5
Table 23
Summary of Contents for GREENSTAR HE combi Series
Page 174: ...7 181 465 347 01 07 50 Appendix...
Page 175: ...7 181 465 347 01 07 Appendix 51...
Page 176: ...Appendix...