SERVICE AND SPARES
Greenstar Ri Compact 6 720 646 610 (2013/12)
43
6.8.12 ELECTRODE ASSEMBLY
To remove the spark electrode assembly:
1. Undo and remove the two nuts securing the electrode assembly
2. Rotate the electrode assembly down and forward to remove from the
Heat exchanger.
▶ Inspect the spark electrodes (2), ionisation probe (3) and ceramics
for signs of contamination or damage, replace as necessary.
▶ If necessary, clean the spark electrodes and ionisation probe with a
plastic scouring pad.
▶ Re-assemble with a new electrode gasket (1),
Fig. 93 Electrode assembly
6.8.13 BURNER HOUSING, BURNER/ GASKET
To remove the burner housing.
1. Release and remove the four spring pins from the castellated nuts.
2. Undo the front two castellated nuts/springs and remove and retain
along with the front two bolts (1).
Slacken the two rear castellated nuts/springs, but do not remove.
Fig. 94 Burner housing
3. Pull the burner housing up and forward to remove.
To remove the burner and gasket.
1. Lift the gasket (1) and burner mesh (2) from the heat exchanger body.
▶ When fitting the burner, ensure that the convex side of the burner
faces down into the heat exchanger.
▶ Always fit a new gasket (1) when re-assembling the heat exchanger.
Fig. 95 Burner and gasket
TIGHTENING DOWN THE BURNER HOUSING
1. Tighten the burner housing castellated nuts [1] down gradually and
evenly and in a rotating sequence.
2. Tighten the castellated nuts down until they “bottom out” on the heat
cell, as indicated by the arrow on the figure below.
▶ Fit the spring clip [2] to secure the castellated nuts, if the hole does
not line up with a space, back the nut off slightly until the hole does
align with the slot.
Fig. 96 Castellated nuts
[1]
Castellated nut
[2]
Spring clip
[3]
Washer
[4]
Burner housing bolts
[5]
Tension springs
CAUTION:
Component replacement:
▶ After replacement of a gas related component, where
a gasket or seal has been disturbed or replaced, check
for gas tightness using a gas sniffer/analyser.
▶ Also after re-assembly, carry out the following checks:
Fan pressure in section 6.5,
Flue gas analysis in section 6.6.
The front two bolts retaining the burner housing are NOT
captive and will drop out when the nuts are removed.
2.
6720646608-89.1W
o
1
2
3
1.
6720646608-90.1W
o
1.
2.
3.
1
6720646608-91.1W
o
1
2
1.
1
6720646610-74.1Wo
4
3
2
5
1.
2.