COMMISSIONING
Greenstar Ri Compact 6 720 646 610 (2013/12)
29
5.4
STARTING THE APPLIANCE
Fig. 52 Control panel
Switching the appliance ON/OFF:
▶ Turn on the mains power supply.
▶ Turn on any external controls
▶ Set the thermostatic radiator controls to maximum temperature
▶ Set the clock/programmer to continuously ON and the room
thermostat to maximum temperature
1. The operation and fault Indicator (2) illuminates blue.
2. Turn the boiler CH temperature control (3) to maximum. The burner
on indicator (4) illuminates GREEN when the burner has lit.
▶ If the boiler fails to light and the boiler goes to flame lock-out, the
BLUE indicator (2) will flash.
3. To reset the lockout; turn the boiler thermostat control to minimum,
then past minimum where the control knob will click at reset position.
Wait five seconds then turn to maximum. The boiler will be reset.
5.4.1 SETTING THE APPLIANCE TO SERVICE MODE
For checking the air/gas ratio, inlet pressure and gas rate, the boiler will
have to be switched into maximum and minimum output. The service
mode can be accessed as follows:
1. Undo the two screw catches.
2. Pull the catches down to release the control panel.
3. Pull the bottom of the panel forward.
4. Lower the control panel to the service position.
5. Release the two screws securing the Installer access cover.
6. Remove the installer access cover.
Fig. 53 Control panel to service position
1. Press the service button for more than five seconds and the boiler will
go into service mode.
2. The red LED will flash when the boiler is in the service mode.
▶ Turn the control knob to “max.” or “min.” for the desired output, the
red LED will flash a five flash sequence for maximum output and a two
flash sequence for minimum output.
▶ Press the service button again briefly to switch out of service mode
and the LED will stop flashing.
Fig. 54 Service mode
▶ When the checks have been completed and the boiler is returned to
normal operation, replace the installer access cover and secure with
the screws.
▶ Return the control panel to normal operating position.
CAUTION:
RUNNING THE APPLIANCE
▶ Never run the appliance when the appliance/system is
empty or partially filled.
1
Burner ON indicator (Green)
2
Boiler operation and fault indicator (Blue)
3
Temperature control
Table 9 Control panel legend
NOTICE:
RESET
▶ Do not press the blue Operation/Fault indicator to
reset the boiler.
6720646610-18.1W
o
1
2
reset
min
max
3
The blue light on the fascia will also flash at the same rate
as the red LED
6720646610-32.2W
o
5.
6.
7.
1.
2.
3.
4.
6720646610-23.1W
o
≈
5 s
2
1
min
max