FORM: PPS SERIES OWNERS MNUL
REV: 05-31-2012
APPR BY: MF
35
complex control procedures of the program and pulse control or to the internal treadmill
parameters is not possible. Only the initial status, the STOP hand mode and the RUN
hand mode are of interest and will be described briefly below.
In the initial status, speed and incline are both zero; the current time and distance are
retained. These are set to 0 when re-starting. It is possible to return to the initial status
with the WOODWAY standard protocol from all RUN modes by entering the command
"treadmill STOP" and then repeating the command again once the treadmill has
stopped (corresponding STOP status, current speed = 0). (Transition from current
STOP status to initial status).
The status STOP manual mode can only be reached from the RUN mode by pressing
the STOP button or by the RS232 command "STOP treadmill" (interruption). No speed
setting commands are accepted in the STOP mode. The current incline, time and
distance remain. Re-start is only possible once the treadmill has come to a standstill by
pressing the "+" button or entering the RS232 command "release treadmill" and then
entering a speed value. In the STOP modes, the STOP button can be pressed or
RS232 command "STOP treadmill" entered to return to the initial status.
Enter the command "release treadmill" from the initial status or STOP manual mode to
reach the RUN manual mode. This is the prerequisite for accepting speed setting
commands. The treadmill knows four different possibilities for changing the speed, with
separate allocated acceleration rates:
"+" / "-" button (physical buttons or RS232 command "Set buttons!")
Speed setting command (RS 232 command "set speed!")
Normal stop (STOP button or RS232 command "STOP treadmill")
Fast stop (only possible by pressing FAST STOP BUTTON), with maximum
acceleration
The maximum, button and RS232 acceleration can be queried in the WOODWAY
standard protocol and the RS232 acceleration set here.
On the railing panel, the pressed "+" button (status) has the same effect as the
command "release treadmill", and the front flank of the "STOP" button has the same
effect as the command "STOP treadmill", each with the corresponding changes in
status. The same effect is achieved when the buttons are allocated RS232 commands.
There is generally no difference between physical and software button control.
The TIME-OUT mode can be activated to monitor correct RS232 communication. This
is useful when on-going cyclic data exchange takes place. This mode offers additional
safety should the PC program fail or if the treadmill extension lead should be
disconnected. If a correct, complete telegram is not received within a set time, the
speed set value is set to 0 and the treadmill is stopped (effect as the STOP button). The
TIME-OUT time can be changed via RS232 between 0.1 ... 9.9 seconds. A value of 0
deactivates the control function. In the WOODWAY standard protocol, the function is
Summary of Contents for PPS 43
Page 26: ...FORM PPS SERIES OWNERS MNUL REV 05 31 2012 APPR BY MF 26 PPS Med 43 PPS Med 55 PPS Med 70...
Page 48: ...FORM PPS SERIES OWNERS MNUL REV 05 31 2012 APPR BY MF 48 WARRANTY INFORMATION Chapter 6...
Page 55: ...FORM PPS SERIES OWNERS MNUL REV 05 31 2012 APPR BY MF 55 966 3929 800 WOODWAY...