Manual
Manual 37223E
37223E
easYgen-3000
easYgen-3000 Series
Series (Package
(Package P1)
P1) -
- Genset
Genset Control
Control
Page
Page 48/67
48/67
©
© Woodward
Woodward
Discrete Inputs: Negative Polarity Signal
Discrete Inputs: Negative Polarity Signal
Discrete input 1
Discrete input 1
6
66
6
Power supply -
Power supply -
Discrete input 2
Discrete input 2
Discrete input 3
Discrete input 3
Discrete input 4
Discrete input 4
Discrete input 5
Discrete input 5
Discrete input 6
Discrete input 6
Discrete input 7
Discrete input 7
Discrete input 8
Discrete input 8
Discrete input 9
Discrete input 9
Discrete input 10
Discrete input 10
Discrete input 11
Discrete input 11
Discrete input 12
Discrete input 12
Pow
Power suppl
er (8 t
y + (8 to 40 Vdc)
o 40 Vdc)
6
67
7
6
68
8
6
69
9
7
70
0
7
71
1
7
72
2
7
73
3
7
74
4
7
75
5
7
76
6
7
77
7
7
78
8
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Power supply -
Figure 6-42: Discrete inputs - alarm/control input - negative signal
Figure 6-42: Discrete inputs - alarm/control input - negative signal
Terminal
Terminal
Description
Description
A
A
max
max
66
66
Discrete
Discrete inputs
inputs -
- GND
GND (common
(common ground)
ground)
2.5
2.5 mm²
mm²
67
67
Discrete
Discrete input
input [DI
[DI 01];
01]; pre-assigned
pre-assigned to
to 'Emergency
'Emergency stop'
stop'
2.5
2.5 mm²
mm²
68
68
Discrete
Discrete input
input [DI
[DI 02];
02]; pre-assigned
pre-assigned to
to 'Start
'Start in
in AUTO'
AUTO'
2.5
2.5 mm²
mm²
69
69
Discrete
Discrete input
input [DI
[DI 03];
03]; pre-assigned
pre-assigned to
to 'Low
'Low oil
oil pressure'
pressure'
2.5
2.5 mm²
mm²
70
70
Discrete
Discrete input
input [DI
[DI 04];
04]; pre-assigned
pre-assigned to
to 'Coolant
'Coolant temperature'
temperature'
2.5
2.5 mm²
mm²
71
71
Discrete
Discrete input
input [DI
[DI 05];
05]; pre-assigned
pre-assigned to
to 'External
'External alarm
alarm acknowledgement'
acknowledgement'
2.5
2.5 mm²
mm²
72
72
Discrete
Discrete input
input [DI
[DI 06];
06]; pre-assigned
pre-assigned to
to 'Enable
'Enable MCB'
MCB'
2.5
2.5 mm²
mm²
73
73
Discrete
Discrete input
input [DI
[DI 07];
07]; fixed
fixed to
to 'Reply
'Reply MCB'
MCB'
2.5
2.5 mm²
mm²
74
74
Discrete
Discrete input
input [DI
[DI 08];
08]; fixed
fixed to
to 'Reply
'Reply GCB'
GCB'
2.5
2.5 mm²
mm²
75
75
Discrete
Discrete input
input [DI
[DI 09]
09]
2.5
2.5 mm²
mm²
76
76
Discrete
Discrete input
input [DI
[DI 10]
10]
2.5
2.5 mm²
mm²
77
77
Discrete
Discrete input
input [DI
[DI 11]
11]
2.5
2.5 mm²
mm²
78
78
Discrete
Discrete input
input [DI
[DI 12]
12]
2.5
2.5 mm²
mm²
Table 6-26: Discrete input - terminal assignment
Table 6-26: Discrete input - terminal assignment
WARNING
WARNING
Discrete Input DI01
Discrete Input DI01 "Emergency Stop" is only a signaling input. This input may only be used t
"Emergency Stop" is only a signaling input. This input may only be used to signal
o signal
that an external emergency stop button has been ac
that an external emergency stop button has been actuated. According to EN 60204, this input is
tuated. According to EN 60204, this input is not
not
approved to be used as the
approved to be used as the emergency stop function. The emergency stop function must be imple-
emergency stop function. The emergency stop function must be imple-
mented external to the control and
mented external to the control and cannot rely on the control to function properly.
cannot rely on the control to function properly.