background image

REPLACEMENT PARTS

WARNING 

 Item  Description 

QTY 

Natural 

Propane

1      Burner Assembly

 

 

 

 

 

Failure to position the parts  in  accordance with  these

  diagrams or  failure  to  use  only parts  specifically 

approved  with  this appliance  may  result in property 

damage or personal injury.

 

SRP

-N

 

     SRP-P

1

9   Small Basalt Stones 

1            G100049              G100049

 20   Lava Rock

          1 

 G100049              G100049

OPTIONAL TOPPING MEDIA:

 

 1

7

 

Burner Clear

 Media 

 1 

 

G100048 

 G100048

1

7

   1

1

     

90 deg. brass elbow

   

  1  

 

C

1000

83

  

 

C

1000

83

 18   Black Glass 

 1           G100032 

 G1000

32

This list contains replaceable parts used in your 

Serpentine

.

All replacement parts should be ordered from your 

retailer or 

from Woodbridge Fireplace Inc. at 1-905-799-5953 or on-line at

 www.woodbridgefp.com 

    

7

 

Gas Supply 

Flex Connector 

1

 

          

C1000

80

             

C1000

80

 

 

1

  

  

W6000

10

 

  W6000

10

2

 

Main Gas Valve

 

1  

  

R

1000

2

 

R

1000

27

 

  

3

 

Pilot Assembly 

         

 1 

   

R1

000

28-SS

    

  R1

000

28-SS

Reducer Bushing 

1

  

  H100007   

  N/A   

    

Orifice 

1  

  

F20001

1

  

  

F20001

3

    

D3

000

90

   

 

D3

0

0

0

90

1  

  

H

100

142

  

 

H100142

 

1

0

     

Shutoff Valve 

DFC Control Board

 

 

DFC Wire Harness

 

1  

  

H

100

141

  

 

H100141

 

  1

2

   

7V 10mA DC adapter

 

1  

 

H

1001

40

 

 

H100140

 

   

1

3

 

Pilot Shield 

D4

00

267

 

 

D4

00

267

  

    

1

4

 

Mount 

Brackk  et        

 

2

 

 F

2

00

022-SS

 

     

 

F200022-SS 

   15       Skytech Remote Control         1  

   PCB 

  PCB

   16       Skytech Remote Receiver  

  1  

   PCB-R  

  PCB-R

    6       

Orifice Flex Connector

      

 1 

  

C1

00

0

09

 

  

C1

00

009

 

Summary of Contents for SRP-N

Page 1: ...ation ope rating and maintenance instructions thoroughlybefore installing or servicing this equipment Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any...

Page 2: ...hould be should not be hung from the appliance or placed on or near the appliance 6 Clothing or other flammable high surface temperatures and should stay away to avoid burns or clothing ignition trica...

Page 3: ...0 W C Max 13 0 W C Never light the appliance without CAUTION Do not remove the metal data plates attached to the Burner These plates contain important information 2 Install the Burner Assembly inside...

Page 4: ...t the clearances are met An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no...

Page 5: ...FIREPLACE STANDARD ENCLOSURE ACCESSING FIREPLACE CONTROLS AND CERTIFICATION TAGS 5 Lift cover off the base and set aside providing access to the wiring harness remote receiver battery pack certificati...

Page 6: ...on all joints Bubbles forming show a leak Correct all leaks at once From Gas Meter 5 W C to 10 5 W C pressure The appliance and its individual shutoff valve must be discon nected from the gas supply...

Page 7: ...BTU h GAS TYPE NATURAL PROPANE ORIFICE SIZE BURNER PORTS PORT SIZE 1 8 1 8 MODEL TOP VIEW SRP N SRP P 46 46 14 24 3 25 9 5 SIDE VIEW FRONT VIEW 14 45 45 7 80 000 10 80 000 35 Specifications SERPENTINE...

Page 8: ...lectronic devices do not try to repair or modify the valve as it may result in a fire or explosion Call a qualified service technician if you have any safety concerns D Do not use this appliance if an...

Page 9: ...t for leaks DO NOT spray solution onto electronic parts WARNING Never use an open flame to check for gas leak DANGER 1 STOP Read the safety information on previous page 2 Turn off all electric power t...

Page 10: ...LATION AND OPERATING INSTRUCTIONS FOR SKYTECH MODEL 1001 T LCD A your service technician or gas supplier of the Receiver is in REMOTE 10 Locate Remote Receiver inside of the unit see Illustrated Parts...

Page 11: ...lycheckedassoonasthe unitis installed andperiodicallyduringnormaloperation The pilot flame must always be present when the fireplace is in operation or connected to the gas line with main shutoff Insp...

Page 12: ...to produce moderate levels of carbon soot where flames Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise Burner flame is too low or too hi...

Page 13: ...ce diameter is too small 4 Flame sensor leads disconnected 1 Pilot flame needs adjusting 1 Gas leak See Warning statement above 1 Gas leak See Warning statement above IMPORTANT Operating unit where im...

Page 14: ...FOR PART DESCRIPTION SEE NEXT PAGE ILLUSTRATED PARTS LIST 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 15 16...

Page 15: ...FOR PART DESCRIPTION SEE NEXT PAGE ILLUSTRATED PARTS LIST Continued BURNER GLASS MEDIA OPTIONAL STONES 17 18 TOPPING GLASS MEDIA optional LAVAROCK optional 20 19...

Page 16: ...Pilot Assembly 6 Volt Battery Backup uses 4 pcs AA Batteries 16 optional...

Page 17: ...arts used in your Serpentine All replacement parts should be ordered from your retailer or from Woodbridge Fireplace Inc at 1 905 799 5953 or on line at www woodbridgefp com 7 Gas Supply Flex Connecto...

Page 18: ...NOTES...

Page 19: ...NOTES...

Page 20: ...the defective components at no charge to the origi nal owner Woodbridge Fireplace will also pay for reasonable labor cost incurred in replacing or repairing such com Woodbridge Fireplace Inc 18A Stra...

Reviews: