CLEANING AND MAINTENANCE
BURNER, PILOT AND CONTROL COMPARTMENT
PILOT FLAME
valve open and the IPS activated (powered)
.
The pilot flame has two distinct
BURNER
Turn off gas before servicing fireplace. It
is recommended that a qualified service
technician perform these check-ups at the
beginning of each heating season.
WARNING
1
flames, one engulfing the flame sensor and the other reaching to the main burner.
Pilot Flame
Keep the control compartment clean by vacuuming or brushing at
least twice a year. Make sure the burner porting, pilot air opening
and burner air opening are free of obstructions at all times.
The flames from the pilot should be visually checked as soon as the
unit
is installed
and periodically during normal operation.
The pilot flame must always be present
when the fireplace is in operation or connected to the gas line with main shutoff
Inspect area around the burner. Remove any lint or foreign material with a brush or vacuum.
The burner must be replaced prior to the appliance being put into operation if it is evident that
the burner is damaged. Please refer to "Illustrated Parts List" for the replacement part number specified
by the manufacturer.
The flame from the burner should be visually checked as soon as the unit is installed and periodically
during operation! Keep the appliance and its burner clean by vacuuming or brushing at least twice a
year. Make sure the burner porting and burner air openings are free of obstructions at all times.
Correc
t
Burner
Flame
1
1