30% or more in total of the remaining wall
area is open and unrestricted.
Open side at least 25% of total wall area
LOCATING YOUR GAS FIREPLACE
Certain materials or items, when placed under or near the appliance, will be subjected to
radiant heat and could become damaged.
3)
4)
Typically an outdoor space is not enclosed but, any enclosure in which the
appliance is used shall comply with one of the following:
1)
When selecting a location for your fireplace, ensure that the clearances are met.
An enclosure with walls on all sides, but at least one
permanent opening at ground level and no overhead
cover.
Within a partial enclosure that includes an overhead
cover and no more that two walls.
Within a partial enclosure that includes an
overhead cover and more than two walls, the
following shall apply:
• At least 25% of the total wall area is completely
open, and
• At least 30% of the remaining wall area is open
and unrestricted
4
2)
This appliance must be installed in an open-air situation with natural ventilation,
without stagnant areas, where gas leakage and products of combustion
are rapidly dispersed by wind and natural convection.