background image

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

www.woodbridgebath.com

1

R

WOODBRIDGE 

IMPORTANT  SAFEGUARDS

READ ALL INSTRUCTIONS BEFORE USING

When using electrical products, especially when children are present, basic safety 
precautions shouldalways be followed, including the following:
1.The appliance is not to be used by persons (including children) with reduced physical, 
   sensory or mental capabilities, or lack of experience and knowledge, unless they have
   been given supervision or instruction.
2.Children being supervised not to play with the appliance.
3.This appliance can be used by children aged from 8 years and above and persons with 
   reduced physical, sensory or mental capabilities or lack of experience and knowledge if 
   they have been given supervision or instruction concerning use of the appliance in a safe
   way and understand the hazards involved.
4.Children shall not play with the appliance.
5.Cleaning and user maintenance shall not be made by children without supervision.

  DANGER 

   –To reduce the risk of electrocution:

1. Do not use while bathing.

3. Do not place in or drop into water or other liquid.
4. Do not reach for a product that has fallen into water. Unplug immediately.
5. Do not wash the main unit or electrical plug with water or detergent.
6. Do not handle the electrical plug with wet hands.
7. Do not put a hand or other staff over the outlet of air dryer or block the outlet of air dryer.
8. Never disassemble,repair or modify this product.
9. During installation, disassembly, repaire and maintenance of the product,the power plug
    must be switched off and water supply be shut off.

WARNING

To reduce the risk of burns, electrocution, fire, or injury to persons.

1. Close supervision is necessary when this product is used by, on, or near children or 
    invalids.
2. Use this product only for its intended use as described in this manual. Do not use
    attachments not recommended by the manufacturer.
3. Never operate this product if it has a damaged cord or plug, if it is not working properly,
    if it has been dropped or damaged, or dropped into water. Return the product to a 
    service center for examination and repair.
4. Keep the cord away from heated surfaces.
5. Never use while sleeping or drowsy.
6. Never drop or insert any object into any opening or hose.
7. Do not use outdoors or operate where aerosol (spray) products are being used or 
    where oxygen is being administered.
8. Connect this product to a properly grounded outlet only. See Grounding Instructions.
9. Do not throw cigarettes and other burning stuff into toilet, otherwise it might cause fire.
10.This product is electric appliance, so it must be placed far away from water. Please 
     don’t drench urine and other liquid to it.
11.Do not lay on side or upside the product during the electrical circuit.
12.It is prohibited to use other electric appliances in the same socket.
13.It is forbidden to use the power extension or unstable loose outlet.
14.The old aging water supply hose can not be used, otherwise it might cause leakage, 
     fire or electrical shock.Installation of the bidet seat should include specified components
     and new water supply hose.

2. Do not place or store product where it can fall or be pulled into a tub or sink.

Summary of Contents for B0970S

Page 1: ...it available for future maintenance or reference Our company reserves the right of final interpretation for this manual The manual is subject to change without notice Customer Service Phone 562 229 0...

Page 2: ...e of the product the power plug must be switched off and water supply be shut off WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this...

Page 3: ...ature at 3 35 C 14 When the room temperature is under zero degree please dry up the water tank to avoid freezing 15 Raise rest room temperature to prevent the toilet from damage due to freezing 16 Whe...

Page 4: ...phon device Anti backflow device Filter device Over 0 2m3 min 6 different level adjustment Thermal fuse Temperature senor Thermostat 250W 1400W 3 1 2 1200W 1400W 110V 120V 50 60Hz Spray cleansing loca...

Page 5: ...bly User ID setting Automatic flushing 6 different level adjustment 50W Quiet soft closing device Auto open and close The seat temperature will automatically lower to level 1 in 10 minutes after using...

Page 6: ...alve Flange Thank you for choosing our products Please rea the instructions carefully before installation and keep it available for future maintenance or refere Our company reserves the right of nal i...

Page 7: ...www woodbridgebath com 6 R WOODBRIDGE TECHNICAL DRAWING The product drawing is for reference only and we reserve the right to modify the appearance of the product 27 1 4 16 1 8 15 3 8 18 5 8...

Page 8: ...bridgebath com Flush Front cleaning button Rear cleaning button Stop Left side PARTS IDENTIFICATION Bumper Seat Ceramic toilet Lid Remote sensing window Drying baffle Rear cleaning Spray nozzle Front...

Page 9: ...dimension of toilet 1 Installation of mating angle valve Line Drain outlet Mating angle valve 2 Cardboard installation Align cardboard with the centerline of drain outlet Draw contour line according t...

Page 10: ...ltion Install sealing flange into drain outlet Install ceramic toilet on corresponding position according to contour line Tips The toilet is heavy and it needs to open the seat cover to carry it by tw...

Page 11: ...tch plug indicator lights on indicating that the power is on Tips Press electric leakage test button prior to usage the reset switch pops up indicating that the leakage protection function is normal E...

Page 12: ...enance 2 Wipe the stain with a soft damp cloth 3 Safety self inspection After cleaning re connect the toilet with the power supply 3 Use soft cloth or soft brush to clean Do not pull or push the spray...

Page 13: ...lve nut 2 Remove filter net 3 Use the brush to clean filter net 4 Reinstall filter and angle valve nut turn on the angle valve and connect power then it can work normally after self inspection No wate...

Page 14: ...to prevent freezing To discharge water 1 Drain out the water inside tank Activate flushing and then turn off angle valve to prevent water inlet 2 Drain out the water inside pipe Unscrew the hose conn...

Page 15: ...he rear portion of body Press rear cleaning button repeatedly then turn on off mobile massage function Press stop button to stop When one circle cleaning is finished and the body remains seated the dr...

Page 16: ...rea User doesn t reach the sensing area in seat Deodorization function keeps working after user leaves If the problems cannot be solved as per above methods please shut off the power and contact servi...

Reviews: