Tips: 
When the main unit is initializing, the “stop” button lights up, after about 1.5s, the blue light 
(ECO light) will switch to red light (power light) .
Under ECO mode, the “stop” button lights up blue light (ECO light). Under working mode, 
the “stop” button lights up red light (power light). Under power-off mode, the “stop” button on 
the main unit lights off. 
Right after main unit starts up, all function levels default to middle level. If the remote control 
is used, all function levels will switch to the levels set by the remote control.

THE ILLUSTRATION OF MAIN UNIT KEYS

The illustration of main unit buttons

1. Press and hold the “Stop” button

for about 3s

on the unit, the 

    unit enters the shutdown mode (red light off), press the “stop button” 
    again, the unit returns to the working mode (lights red).

In the 

    shutdown mode, except for the “Stop” button on the main unit, any 
    button (including the unit and the remote control) is invalid

.

  

2. When the user is seated, press the “Stop” button on the main unit to 
    stop the feminine washing, rear washing or drying function. When
    the user is not seated, press the “Stop” button on the main unit 
    repeatedly. The main unit switches over between working mode
    (red light) and power save mode (blue light).

1. When people is seated, press "rear cleaning" button, to wash the 
    rear portion of body; Press "rear cleaning" button repeatedly, then 
    turn on/off mobile massage function; Press "stop" button to stop. 
    When one circle cleaning is finished and the body remains seated, 
    the dry function will be automatically turn on and will stop after one
    cycle. 

2. When no one is seated, press "rear cleaning" button, the wand will 
    stretch out ,people can wash the nozzle and wand manually, press
    "stop" button, the wand will retracts.

When people is seated, press "Front cleaning" button,  to wash the
front portion of body; Press "Front cleaning" button epeatedly, then
turn on/off mobile massage function; Press "stop" button to stop. 
When one circle cleaning is finished and the body remains seated, 
the dry function will be automatically turn on and will stop after one 
cycle. 

1.When the user is seated, long press the “flushing” button

for about 

   3s

on the main unit to turn on the drying function. After drying for one 

   cycle, it will stop automatically. During the drying process, press the 
   “Stop” button to stop the drying function. 
2.In the non-off mode, short press the “flushing” button on the main unit
   to turn on the flush function. [Under the rear wash or the femail wash 
   function, the flush function is invalid; when the nozzle is manually 
   cleaned, the flush function is activated after the nozzle is fully extended 
   and retracted into position]

Flush

  Front 
washing/
massage

  Rear 
washing/
massage

Stop

3.In the case of power failure, press and hold “flush” button on the main 
   unit (for about 1s) to flush manually (full flush). 

Summary of Contents for B0970S

Page 1: ...it available for future maintenance or reference Our company reserves the right of final interpretation for this manual The manual is subject to change without notice Customer Service Phone 562 229 0...

Page 2: ...e of the product the power plug must be switched off and water supply be shut off WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this...

Page 3: ...ature at 3 35 C 14 When the room temperature is under zero degree please dry up the water tank to avoid freezing 15 Raise rest room temperature to prevent the toilet from damage due to freezing 16 Whe...

Page 4: ...phon device Anti backflow device Filter device Over 0 2m3 min 6 different level adjustment Thermal fuse Temperature senor Thermostat 250W 1400W 3 1 2 1200W 1400W 110V 120V 50 60Hz Spray cleansing loca...

Page 5: ...bly User ID setting Automatic flushing 6 different level adjustment 50W Quiet soft closing device Auto open and close The seat temperature will automatically lower to level 1 in 10 minutes after using...

Page 6: ...alve Flange Thank you for choosing our products Please rea the instructions carefully before installation and keep it available for future maintenance or refere Our company reserves the right of nal i...

Page 7: ...www woodbridgebath com 6 R WOODBRIDGE TECHNICAL DRAWING The product drawing is for reference only and we reserve the right to modify the appearance of the product 27 1 4 16 1 8 15 3 8 18 5 8...

Page 8: ...bridgebath com Flush Front cleaning button Rear cleaning button Stop Left side PARTS IDENTIFICATION Bumper Seat Ceramic toilet Lid Remote sensing window Drying baffle Rear cleaning Spray nozzle Front...

Page 9: ...dimension of toilet 1 Installation of mating angle valve Line Drain outlet Mating angle valve 2 Cardboard installation Align cardboard with the centerline of drain outlet Draw contour line according t...

Page 10: ...ltion Install sealing flange into drain outlet Install ceramic toilet on corresponding position according to contour line Tips The toilet is heavy and it needs to open the seat cover to carry it by tw...

Page 11: ...tch plug indicator lights on indicating that the power is on Tips Press electric leakage test button prior to usage the reset switch pops up indicating that the leakage protection function is normal E...

Page 12: ...enance 2 Wipe the stain with a soft damp cloth 3 Safety self inspection After cleaning re connect the toilet with the power supply 3 Use soft cloth or soft brush to clean Do not pull or push the spray...

Page 13: ...lve nut 2 Remove filter net 3 Use the brush to clean filter net 4 Reinstall filter and angle valve nut turn on the angle valve and connect power then it can work normally after self inspection No wate...

Page 14: ...to prevent freezing To discharge water 1 Drain out the water inside tank Activate flushing and then turn off angle valve to prevent water inlet 2 Drain out the water inside pipe Unscrew the hose conn...

Page 15: ...he rear portion of body Press rear cleaning button repeatedly then turn on off mobile massage function Press stop button to stop When one circle cleaning is finished and the body remains seated the dr...

Page 16: ...rea User doesn t reach the sensing area in seat Deodorization function keeps working after user leaves If the problems cannot be solved as per above methods please shut off the power and contact servi...