UTILITIES SPECIFICATIONS
Gas
19mm (3/4") FNPT gas inlet
151,000 BTU/hr Natural Gas (NG)
OR
151,000 BTU/hr Propane (LP)
Maximum gas inlet pressure
34 mbar (1/2 psi or 14 inches W.C.)
Electrical
120 VAC, 2 A, 60 Hz
Optional: 240 VAC, 1 A, 60 Hz
All utility connections made on the back
of the oven control box. Remove front or
rear panel for access Use utility knockouts
(provided) to route gas and electrical
supplies. Refer to data plate when installing.
Venting
The Phoenix must be vented using an approved
chimney, or an exhaust hood constructed and
installed in accordance with all relevant local and
national codes. Remove round collar if venting with
an exhaust hood
Side view
Rear view
Plan view
G
54 1/4"
1380mm
62"
1570mm
42 1/4"
1070mm
46 1/2"
1180mm
O
10"
250mm ID
AIR INTAKE
24 1/2"
620mm
7 1/2"
190mm
27 1/4"
690mm
8"
200mm
20 1/4"
510mm
4 1/4"
110mm
6"
150mm
9 3/4"
250mm
10 1/4"
260mm
8"
200mm
O
69 3/4"
1770mm
7 1/2"
190mm
47"
1200mm
37"
940mm
29 3/4"
760mm
40"
1020mm
6"
150mm
3 1/2"
90mm
O
1 1/2"
40mm
9 1/2"
240mm
O
6 1/2"
160mm
6 1/2"
160mm
Front view
Actual weight
2,200 lbs.
Shipping weight
2,500 lbs.
Air intake: Do not
facade or cover over
Must be left
removable for service
Knockouts provided
on Rear Panel for gas/
electrical connection
Rear Panel MUST
be installed
Dual Burner Phoenix Installation
and Operation Manual
PG
7
OF
32
M0030.10 JANUARY 2020
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TEL
+1.360.650.1111
FAX
+1.360.650.1166
woodstone-corp.com
PX-4355-LR SPECIFICATIONS