Maximum inlet gas pressure must not exceed 34 mbar (14" W.C. or 1/2 psi)
GAS INLET PRESSURE
For ovens running on natural gas, an inlet pressure of 17.5–25mbar (7 to 10" W.C.) is recommended to ensure optimum
oven performance. Incoming gas pressure below this range will affect oven performance, the lower the pressure the greater
the negative impact. If the gas supply pressure is greater than 34mbar (14" W.C. or 1/2 psi), an external regulator, supplied
by others, is REQUIRED to lower the gas pressure to the acceptable range. Issues caused by low or high gas pressure are
installation issues, and will not be covered under the Warranty.
For ovens running on LP, the recommended inlet pressure to ensure optimum oven performance is 25–30mbar (10 to 12"
W.C.) Incoming gas pressure below this range will affect oven performance, the lower the pressure the greater the negative
impact. If the gas supply pressure is greater than 34mbar (14" W.C. or 1/2 psi), an external regulator, supplied by others,
is REQUIRED to lower the gas pressure to the acceptable range. Issues caused by low or high gas pressure are installation
issues, and will not be covered under the Warranty.
For all installations, follow best practices for proper gas line pipe sizing for the line serving the oven. To insure proper
operation, all gas piping and fittings leading up to the oven should have an inside diameter equal to or greater than that
of the oven gas connection. Also make sure that a readily accessible shut off valve (supplied by others) is installed near
the oven, and in accordance with all applicable codes. Shut off valves must be of the full-flow type, and not introduce any
restriction into the gas line.
The connection to the oven should be hard-piped whenever feasible. If this is not possible, use a properly sized flexible
connector approved for this application. When using a flexible connector make sure that its design does not present any
reduction in pipe diameter or other restriction. Oven issues caused by improper pipe sizing, improper shut off valves,
restrictive connectors, or any other deficiency in the gas supply design or installation will not be covered under the oven
warranty.
15.
Install the rear panel, front panel and toe kick using the 1/4-20 screws provided. The front panel on the oven must not be
covered, so as to allow access for service to the oven components. The oven should be bolted to the floor using the holes
provided at the base of the stand.
NOTE: REAR PANEL MUST BE INSTALLED FOR THE PROPER FUNCTIONING OF THE OVEN.
Dual Burner Phoenix Installation
and Operation Manual
PG
23
OF
32
M0030.10 JANUARY 2020
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TEL
+1.360.650.1111
FAX
+1.360.650.1166
woodstone-corp.com
UTILITY CONNECTIONS