PG
6
OF
48
M0037.09 SEPTEMBER 2019
Mountain Series CE
Installation and Operation Manual
INSTALLATION CLEARANCES
Installation and servicing of this product could expose you to glasswool/ceramic fibers as well as
calcium silicate dust. ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING OR
SERVICING THIS APPLIANCE. Please read this entire manual before you install the oven. Failure to follow
instructions may result in property damage, bodily injury or even death. Contact your local building or
fire officials about restrictions and installation inspection in your area.
CLEARANCES
1.
The Wood Stone Mountain Series oven must have a
minimum 25 mm (1") clearance to combustibles from all sides,
and 152mm (6") clearance to combustibles from the top
(see INSTALLATION CLEARANCES section on next page)� If
building a facade that will contact the oven, use completely non-combustible materials*� Please note that standard Drywall (or
Sheetrock) is considered a combustible�
2.
If enclosing the oven, any facade materials 152 mm (6") to either side of the oven doorway and above must be constructed
of non-combustible building materials� All materials in direct contact with, or attached to the oven body, must be non-
combustible�
3.
Install this oven only on a non-combustible floor surface�
For models that also burn wood, also provide a non-combustible floor
covering at least 762 mm (30") to each side of, and 914 mm (36") in front of the door opening.
The floor design and construction must be adequate to handle the weight of the oven� See
woodstone-corp.com
for floor
loading information�
*When NON-COMBUSTIBLE building materials contact the body of the appliance, the clearances to combustibles are transferred
to those non-combustibles�
NOTICE:
Only non-combustible materials may be applied directly to the oven�
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS OVEN BE
INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
WARNING:
DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL THE OVEN. FAILURE TO FOLLOW INSTRUCTIONS MAY
RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. CONTACT YOUR LOCAL BUILDING OR FIRE
OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
INSTALLATION CLEARANCES