PG
41
OF
48
M0037.09 SEPTEMBER 2019
Mountain Series CE
Installation and Operation Manual
OPERATIONAL SEQUENCE
RFG-(W) CE OVEN BURNER OPERATION SEQUENCE
W-IR CE OVEN BURNER OPERATION SEQUENCE
Pilot lights�
Power ON�
ICS2 Module powers Igniter
and opens Pilot valve�
Pilot does not
light, ICS2 Module
times out, Type 2
Controllers flash
“chec”�
ICS2 module senses Pilot
flame, Turns Igniter OFF,
Burner lights, Dome Flame
light comes ON�
Burner remains ON until
oven control is turned OFF�
Pilot lights�
Power ON
RFG-IR-(W) CE OVEN BURNER OPERATION SEQUENCE
ICS2 Module (Radiant burner) powers
Igniter and opens Pilot valve�
Pilot does not light,
ICS2 Module times out�
Radiant burner remains ON until
oven Controller is turned OFF�
Floor temperature is below the
Hearth Set Point
– Controller sends
power to ICS1 Module, ICS1 powers
Igniter and opens Pilot valve�
Pilot lights, ICS1 senses Pilot flame, Igniter
OFF, ICS1 powers SV-1 valve, Underfloor
Infrared (IR) burner lights, Hearth Heat
light comes ON�
Floor reaches the Hearth Set Point
temperature
– Controller turns OFF
power to ICS1 and Underfloor IR burner
shuts OFF�
Pilot does not light, ICS1 times out,
Controller flashes “chec”�
Floor temperature is above the
Hearth Set Point
– No action�
ICS2 senses Pilot flame, Igniter OFF,
ICS2 powers SV-2 valve, Radiant
burner lights, Dome Flame Indicator
Light comes ON�
Note:
Primary heat
source for
this model is
the wood fire.
Floor reaches Hearth Set
Point
– Controller turns OFF
power to ICS1 to turn OFF
IR burner�
Pilot does not light, ICS1
times out, Controller will
flash “chec”�
Floor temperature
above Hearth Set Point
– No action�
Power ON�
Pilot lights, ICS1 senses
Pilot flame, Igniter OFF, ICS1
powers SV-1 valve, Infrared
burner lights, Hearth Heat light
comes ON�
Floor temperature below
Hearth Set Point
– Controller
sends power to ICS1 Module,
ICS1 powers Igniter and
opens Pilot valve�
PERIODIC THERMAL CLEANING