VENTING DO’S & DON’TS
HOOD INSTALLATION WITH DECORATIVE FACADE WALL/OVEN ENCLOSURE
For installations where a hood is being used with a decorative facade wall or oven enclosure, it will be necessary to both seal
the gap between the facade wall and the top of the oven, and the gaps at the sides of the hood between the facade wall and
the front of the oven� This will prevent air from being pulled up the sides of the oven from below by the hood� It will also prevent
debris, etc� from falling into the facade wall�
Note that the hood extends out beyond the face
of the oven� DO NOT extend the oven facade wall
into the oven hood� The wall beneath the hood
must stop at the top of the oven� To allow for
proper function of the hood, filter removal and
hood maintenance, you must provide a minimum
of 8 inches of clearance between the front face of
the facade wall and the front of the hood�
Additional flashing detail
Wall stud
Shield
flashing
to be
flush
with
top of
oven
Flashing piece
by installer
Acceptable venting
Acceptable venting