PG
17
OF
48
M0037.09 SEPTEMBER 2019
Mountain Series CE
Installation and Operation Manual
GAS SPECIFICATIONS
PROPANE (LP)
Gas Supply and Pressure
MOUNTAIN SERIES MODELS
EN 437 Gas Group
|
3+
|
3B/P
|
3B/P
|
3P
Inlet Pressure (mbar)
28-30/37/50
*
30/37
*
50
*
30/37/50
*
Declared Input (kW)
|
3+
|
3B/P
|
3B/P
|
3P
MS-4-RFG-CE-LP
17�6
23�5
23�5
17�6
MS-4-RFG-IR-CE-LP
29�9
40
40
29�9
MS-5-RFG-CE-LP
27�5
33�6
33�6
27�5
MS-5-RFG-IR-CE-LP
46�6
57
57
46�6
MS-6-RFG-CE-LP
27�5
33�6
33�6
27�5
MS-6-RFG-IR-CE-LP
46�6
57
57
46�6
MS-7-RFG-CE-LP
41�6
41�6
41�6
41�6
MS-7-RFG-IR-CE-LP
66�5
66�5
66�5
66�5
Factory Specified
Pressures at Gas Valve
Outlet (mbar)
|
3+
|
3B/P
|
3B/P
|
3P
SV-1 SV-2
SV-1 SV-2 SV-1 SV-2 SV-1 SV-2
MS-4-RFG-CE-LP
-
13�6
-
13�6
-
13�6
-
17�4
MS-4-RFG-IR-CE-LP
17�5
13�6
17�5 13�6
17�5 13�6
22�4 17�4
MS-5-RFG-CE-LP
-
15�6
-
15�6
-
15�6
-
20
MS-5-RFG-IR-CE-LP
17�5
15�6
17�5 15�6
17�5 15�6
22�4
20
MS-6-RFG-CE-LP
-
15�6
-
15�6
-
15�6
-
20
MS-6-RFG-IR-CE-LP
17�5
15�6
17�5 15�6
17�5 15�6
22�4
20
MS-7-RFG-CE-LP
-
18�4
-
18�4
-
18�4
-
22�7
MS-7-RFG-IR-CE-LP
17�9
18�4
17�9 18�4
17�9 18�4
22�9 22�7
Propane (LP): Maximum inlet gas pressure to the oven, after the external regulator (if used),
must not exceed 34 mbar (14" W.C. or 1/2 psi)
SCOPE OF APPROVALS
G31 @ 37 mbar
*
- I
3P(37)
-
BE, CH, CZ, ES, FR, GB, GR, HR, IE, IT, LT, NL, PL, PT, SI, SK, TR
G31 @ 50 mbar
*
- I
3P(50)
-
AT, BE, CH, CZ, DE, ES, FR, GB, NL, SK
G30 @ 28-30 mbar, 37 mbar
*
- I
3+(28-30/37)
-
BE, CH, CY, CZ, ES, FR, GB, GR, IE, IT, LT, PT, SI, SK, TR
G30 @ 30 mbar - I
3B/P(30)
-
AT, BE, CY, CZ, DE, DK, EE, FR, GB, HR, HU, IT, LT, NL, NO, PL, RO, SE, SI, SK
G30 @ 50 mbar
*
- I
3B/P(50)
-
AT, CH, CY, CZ, DE, FR, SK