SPECIFICATIONS
Blade Motor Specifications
7
7-3
MHdoc031116
Specifications
7.3
Blade Motor Specifications
See Table 7-5.
See the table below for motor specifications for TVS.
See Table 7-6.
The noise level of the Wood-Mizer TVS is given below
12
.
Motor Type
Manufacturer
Model
Power
Other Specifications
Blade Motor
Indukta, Poland
Indukta, Poland
Siemens, Germany
SG132S -2B
HM
PSg-132 S2 -
HM
1LE1002
1DA33-4AA0
7,5kW
11kW
15kW
400 V/50Hz; 13,9 Amp;
2920 r.p.m.
400 V/50Hz; 20,3 Amp;
2920 r.p.m.
460V/60Hz; 26,5A
3530 r.p.m.
Feed Chain
Motor
Besel, Poland
SKh80X-4C1
IMB14/1-162
1,1kW
400 V/50Hz; 2,3 Amp;
1380 r.p.m.
TABLE 7-5
Noise Level L
EX8
TVS
93,5 dB (A)
TABLE 7-6
1. The noise level measurement was taken in accordance with PN-EN ISO 3746
Standard . The noise exposure level given above concerns an 8-hour work day.
2. The measured values refer to emission levels, not necessarily to noise levels in the
workplace. Although there is a relation between emission levels and exposure levels, it is
not possible to determine with certainty if preventives are needed or are not needed.
The factors affecting a current level of noise exposure during work are inter alia room
characteristics and characteristics of other noise sources, e.g. number of machines and
machining operations nearby. Also, the permissible exposure level value may vary
depending on country. This information enables the machine’s user to better identify
hazards and a risk .
Summary of Contents for TVSE11S - SC
Page 1: ......
Page 2: ......
Page 24: ...OPERATION TVS Setup 2 2 7 MHdoc031116 Operation the pictures below FIG 2 2 FIG 2 2 tvs_184A...
Page 51: ...Troubleshooting Setworks Malfunction Troubleshooting TVS_SWdoc031116 4 4 4 PHOTO 4 3 PHOTO 4 4...
Page 52: ...Troubleshooting Setworks Malfunction 4 4 5 TVS_SWdoc031116 Troubleshooting PHOTO 4 5...