Setup & Operation
Errors and messages
EGdoc013119
4-31
4
4.2.19
Errors and messages
The operator is informed about the occurrence of errors by:
- Indicator lights located under the operator's panel. The indicator lights show the status of the
safeguards:
a) COVERS – green light indicates that the blade covers are closed.
b) TENSION – green light indicates that the blade is correctly tensioned
c) AC – red light indicates that the safeguards of the following components were activated: forward/reverse
feed: left or right motor, hydraulic pump of the hydraulic unit, conveyor belt, up/down inverter,
forward/backward inverter, main motor.
d) ACC – red light indicates that the safeguards of the debarker motor, debarker arm travel motor, debarker
arm rotation motor and the blade guide arm motor were activated.
- Messages appearing on the display: errors diagnosed by the PLC controller.
Errors resulting from inverter malfunction cause the appearance of the window with a description of the error:
and the appearance of scrolling text at the bottom of the display:
Feed drive error saw head drive error