SERIAL PORT / SERIAL PROTOCOL
9-pin D-Sub connector
on unit, male, front side
5
9
2
7
3 4
8
1
6
Pins:
2: RX, 3: TX, 5: GND, 7: RTS, 8: CTS
Baud rate:
9200, 19200, 38400, 57600 or 115200 (selectable)
databits: 8, stopbit: 1, parity: no
Please note: DecimaI-Codes (=ASCII-Codes or Hex-Codes) must be sent as one
single byte (e.g. 199 and not: 1 + 1 + 9) !
The serial port can be used to control the Visualizer through an external device, like a remote control
system for a complete conference room.
A detailed description of the serial protocol (including status
report and position setting) can be
downloaded from our website:
http://www.wolfvision.com/support.
DVI PORT
13
Pin 24
Pin 8
Pin 1
Pin 9
Pin 17
C4
C1
C2
C3
C5
1
- T.M.D.S. Data2-
9
-
T.M.D.S. Data1-
17
- T.M.D.S. Data0-
2
- T.M.D.S. Data2+
10
-
T.M.D.S. Data1+
18
- T.M.D.S. Data0+
3
- T.M.D.S. Data2/4 Shield
11
-
T.M.D.S. Data1/3 Shield
18
- T.M.D.S. Data0+
4
- T.M.D.S. Data4-
(*)
12
- T.M.D.S. Data3-
(*)
19
- T.M.D.S. Data0/5 Shield
5
- T.M.D.S. Data4+
(*)
13
- T.M.D.S. Data3+
(*)
20
- T.M.D.S. Data5-
(*)
6
- DDC Clock
14 - +5V Power
21
- T.M.D.S. Data5+
(*)
7
- DDC Data
15
- Ground (return for +5V,
22
- T.M.D.S. Clock+
8
- Analog Vertical Sync
HSync and Vsync)
23
- T.M.D.S. Clock-
C1
- Analog Red
16
- Hot Plug Detect
24
- Analog Vertical Sync
C4
- Analog Horizontal Sync
C2
- Analog Green
C3
- Analog Blue
C - Analog Ground
(analog R, G & B return)
*...not used
Before changing a fuse disconnect the power cable. The fuse
(#34)
is situated behind a small lid above the power socket and the main
power switch. It can easily be opened with a small screwdriver etc..
Please put the new fuse(s) carefully into the socket, and put the socket
the right way round into the socket holder.
The type of fuse is: T 3,15A. Do not use any other type !
Change the fuse for a new one and switch the unit on. If the fuse fails
again contact your WolfVision Visualizer dealer!
EXCHANGING A FUSE
IMPORTANT
MIRROR - CLEANING
Mirror:
Please note that dust on the base mirror
(#2)
inside the unit
has little effect on the picture quality (as it is out of the
focal range). However the top mirror
(#3)
always has to be kept clean!
Wipe the mirror gently with the supplied WolfVision cleaning tissue!
Normal dry cleaning or cleaning together with breathing a bit on the mirror should be sufficient
(If not, use a special optical cleaner only!)
Please note: Switch off the power before cleaning a mirror in order to make sure that the Laser Center
Marker is off.
CAUTION: Sensitive front coated mirror!
Move the tissue in vertical direction only ! (horizontal scratches
would cause ugly reflections) Avoid high pressure !
DO NOT USE ORDINARY GLASS CLEANER OR ALCOHOL
- THE RESULT WOULD BE A SLIGHTLY BLUE MIRROR SURFACE !
The glass covering the mirror inside the unit should also be kept clean.
Cabinet:
Clean the cabinet by gently wiping it with a soft cloth.
Never use strong cleaning agents such as benzene or alcohol!