11
+ 12V
GND
When a locked power connector and/or other power supply is necessary, the
supplied power connector can be used.
The power supply is optional if Power over Ethernet (PoE) is used
(see page 12)
.
The power source equipment shall comply with all applicable local and
national codes related to safety.
Power Plug
DVI-I Port
1
- T.M.D.S. Data2-
9
-
T.M.D.S. Data1-
17
- T.M.D.S. Data0-
2
- T.M.D.S. Data2+
10
-
T.M.D.S. Data1+
18
- T.M.D.S. Data0+
3
- T.M.D.S. Data2/4 Shield
11
-
T.M.D.S. Data1/3 Shield
18
- T.M.D.S. Data0+
4
- T.M.D.S. Data4-
(*)
12
- T.M.D.S. Data3-
(*)
19
- T.M.D.S. Data0/5 Shield
5
- T.M.D.S. Data4+
(*)
13
- T.M.D.S. Data3+
(*)
20
- T.M.D.S. Data5-
(*)
6
- DDC Clock
14
- +5V Power
21
- T.M.D.S. Data5+
(*)
7
- DDC Data
15
- Ground (return for +5V,
22
- T.M.D.S. Clock+
8
- Analog Vertical Sync
HSync and Vsync)
23
- T.M.D.S. Clock-
C1
- Analog Red
16
- Hot Plug Detect
24
- Analog Vertical Sync
C4
- Analog Horizontal Sync
C2
- Analog Green
C3
- Analog Blue
C5 - Analog Ground
*...not used
(analog R, G & B return)
m
Pin 24
Pin 8
Pin 1
Pin 9
Pin 17
C4
C1
C2
C3
C5
The DVI-I port
(#13)
provides digital and analog signals.
For using HDMI, a DVI-HDMI cable or adapter is required.
In some rooms, the built-in IR-receiver may
. In this case connect the optional external
receiver to the IR-SENSOR plug
(#12)
and position the IR-sensor somewhere on the ceiling (or in
the room)
not be enough
infrared
where the users normally point the remote control at.
External Infrared (IR) Sensor
(optional)
RS-232, Serial Control Input
9-pin D-Sub connector
on unit; male
(front side)
5
9
2
7
3 4
8
1
6
The serial port
(#10)
can be used to control the EYE-12 through an external device, such as a room control
system.
Pins:
2: RX, 3: TX, 5: GND
Baud Rate: 9200, 19200, 38400, 57600 or 115200 (selectable)
databits: 8, stopbit: 1, parity: no
The baud rate can be changed in the on-screen extra menu by keeping
pressed the menu key until it appears
(see page 10)
.
RGB Port
1 - Analog Red video
6 - Red return
11 - N/C Not connected
2 - Analog Green video
7 - Green return
12 - SDA I²C data
3 - Analog Blue video
8 - Blue return
13 - HSync Horizontal sync
4 - N/C Not connected
9 - SENSE +5 V DC from Visualizer
14 - VSync Vertical sync
5 - GND Ground
10 - GND Ground (VSync, DDC)
15 - SCL I²C clock
1
11
5
15
15-pin D-Sub HD
connector female
(front side, unit)
The RGB port
(#11)
provides analog RGBHV signal.
DVI-I connector female
(front side, unit)
The complete protocol can be found on our internet website under:
www.wolfvision.com
(Support)