Control / Function / Commissioning
ON / OFF switch
DHW
temperature
selector
Pressure
gauge
Reset
button
Heating water
temperature
selector
Illuminated
signal ring
Thermometer
9
1
2
8
3
7
4
6
5
DHW temperature selector
Settings 1-9 correspond with a DHW temperature of 40-65 °C with gas combi
boilers, or 15-65 °C with gas boilers with a cylinder. Combined with a control
thermostat for wall mounted gas fi red boilers, the adjustment at the DHW
temperature selector is disabled; instead the temperature is selected at the
boiler control thermostat.
2
8
3
7
4
6
5
Heating water temperature selector
Settings 2-8 correspond to a heating water temperature of 40-80 °C. Combined
with a temperature controller for wall mounted gas fi red boilers, the adjustment
at the heating water thermostat is disabled; instead the temperature is selected
at the boiler temperature controller.
Signal ring as
status display
Display
Explanation
Flashing green
Standby (power supply ON, burner OFF)
Constant green light Heat demand: pump running, burner OFF
Flashing yellow
Emissions test mode
Constant yellow light Burner ON, fl ame steady
Flashing red
Fault
Reset
A fault is reset by pressing the reset button which will also restart the system.
Pressing the reset button reactivates the system, if there was no fault.